Operation

PILOT

ON

OFF

PILOT

ADJ

LO

HI

TPTH

TH

TP

Piezo Ignitor

Gas
Control Knob

Regulator
Control Knob

HV104

Fig. 19 Valve controls.

ST232

Fig. 21 Pilot assembly location.

Natural Pilot

LP Pilot

Your First Fire

Read these instructions carefully and familiarize
yourself with the burner controls of this heater.

The JUVSR uses a Honeywell control valve that allows
thermostatic, on/off switch regulation and has a sepa-
rate Piezo ignition button. (Fig. 19 or 20)

The JUVSM is equipped with an SIT control valve for
manual use only.

Locate the Pilot assembly to the right behind the
burner. (Fig. 21) Follow the lighting instructions on page
14 exactly.

For the first fire, allow the stove to operate continuously
for six hours without using the fan. During the first fire, it
is not unusual to smell some odor associated with new
logs, paint and metal being heated. Odors should
dissipate within a few hours or so, however, you can
open a window to provide plenty of fresh air to alleviate
this condition.

Pilot and Burner Inspection

Each time you light your heater, check that the pilot
flame and burner flame pattern are as shown in Figures
23 and 24. If flame patterns are incorrect, turn the
heater off. See

Troubleshooting, page 16.

Do not operate the heater until the pilot flame is correct.

Follow regular maintenance procedures as described
on page 15.

HI

OFF

PILOT

LO

Piezo Ignitor

ST573

Fig. 20 SIT control valve.