OTHER CAUTIONS

Dust or other foreign matter adhering to the print paper or the sheet cartridge, or deformation resulting from exposure to
extremely low or high temperatures could cause loss of color, uneven color or lines, or wrinkles in the print images.

NOTE:
MEMORIZED IMAGES ARE STORED IN VOLATILE MEMORY AND MAY BE LOST IN THE EVENT OF POWER
FLUCTUATION OR MALFUNCTION.

As for paper sheet set, refer to page 21, “Options”.

CONNECTING DEVICES

Read thoroughly the Safety Notices, Cautions and “Operating Precautions” of the instruction booklets for the other devices
connected with the unit.

CAUTION ON RELOCATING

When transporting the unit, make sure it is not likely to be subjected to impacts. This can be a primary cause for damage.
Before moving the unit, make sure to disconnect the power cord from the power outlet, and the cables from the connected
devices.

SAFETY CHECKS

Periods:

According to the recommendations of the manufacturer of medical device.

Scope: a)

Visual inspection

Housing, leads, controls, displays, labels/ markings, accessories, operation manual.

b)

Functionality test

Testing of functions (according to operation manual) as well as compatibility and usability of device and accessories.

c)

Electrical test

Testing of electrical safety of the system according to EN60601-1.

High humidity or dust

Avoid locations with high humidity and dust in order to avoid malfunction.

Also avoid locations subject to corrosive gasses and smoke.

Heat

Direct sunlight, heaters or other heat sources may deform the housing and subsequently cause malfunctioning.

TECHNICAL DESCRIPTION

The supplier will make available on request such circuit diagrams, component part lists, descriptions, calibration instructions or other information

which will assist the USER’s appropriately qualified technical personnel to repair those parts of the EQUIPMENT which are classified by the

manufacturer as repairable.

The use of ACCESSORY equipment not complying with the equivalent safety requirements of this equipment may lead to a reduced level of

safety of the resulting system. Consideration relating to the choice shall include:

- use of the accessory in the PATIENT VICINITY

- evidence that the safety certification of the ACCESSORY has been performed in accordance to the appropriate EN60601-1 and/or EN60601-1-

1 harmonized national standard.

The transportation and storage environmental conditions are:

Temperature : -20

°

C - +60

°

C (-4

°

F - +140

°

F)

Humidity : 90%RH or less at 40

°

C(104

°

F)

Atmospheric pressure : 500 hPa - 1060 hPa

SAFETY PRECAUTIONS

WARNING :

Use the USB cable according to the recommendations as below, in order to comply with EN60601-1-2.
The USB cable with appropriate plug should be 2m long or shorter, comply with USB 2.0 standard High speed require-
ments and USB IF (USB Implementers Forum) approved.

Information:

This equipment complies with EN55011, class B, group 1.