Cdvx series direct vent gas fireplace, Rear wall installation twist lock pipe – Majestic Appliances Builder Direct Vent 36CDVXTRN User Manual

Page 14

Advertising
background image

14

CDVX Series Direct Vent Gas Fireplace

20012253

Minimum clearances between vent pipe and com-
bustible materials are as follows:

Top - 1” (25 mm)
Sides - 1” (25 mm)
Bottom - 1” (25 mm)

The maximum horizontal distance between the end
of the transition elbow in a corner application and the
outside face of the rear wall is 20” (508 mm). (Fig. 16)

Only one 45° elbow is allowed in these installations.

Top View

Straight Venting

Fig. 15 Rear vent applications.

20"

(508 mm)

Max.

�������
���������
���������
�����

FP1598

20” (508 mm)

Max.

FP1188

Fig. 16 Rear vent application, one 45° elbow.

Rear Wall Installation

Twist Lock Pipe

STEP 1
Locate vent opening on the wall. To locate hole center
consult with appropriate fireplace dimensions, Page 4.
Frame as shown below.
Combustible Walls (Fig. 17): Cut a 9³⁄₈”H x 9³⁄₈” W
(240 x 240 mm) hole through the exterior wall and
frame as shown. For 7TCRVT1320 cut a 10³⁄₈”H x 9³⁄₈”
W (264 x 240 mm) hole.
Noncombustible Walls (Fig. 17): Hole opening must
be 7¹⁄₂” (190 mm) in diameter.
STEP 2
Install interior firestop as shown in Figure 18.
STEP 3
Remove telescoping collar from termination.

������
��������
������

Firestop

FP1600

Fig. 18 Install firestop.

Bend Tab

STEP 4
Bend tab on outer casing up and insert collar onto fire-
place collars. (Fig. 18)
STEP 5
Twist the termination collar so it locks onto fireplace col-
lars. Run screw through tab to keep collar from turning.
(Fig. 19)
STEP 6
Slide fireplace into position.
STEP 7
From the outside of the house, slide the termination
onto the collars.
STEP 8
Secure the termination to the house with the four (4)
screws provided.

VO584-100
Vent Opening
2/99 djt

Vent Opening for Combustible Wall

9³⁄₈”

(240 mm)

9³⁄₈”

(240 mm)

Fireplace Hearth

Framing

Detail

Opening for Noncom-

bustible Wall

7¹⁄₂”

(190 mm)

VO584-100

Fig. 17 Locate vent opening on wall.

When using all

venting except

7TCRVT1320

9³⁄₈”

(240 mm)

10³⁄₈”

(264 mm)

When using
7TCRVT1320
venting Only