77

Explanation of functions (parameters)

2

F

UNCT

IO

NS

2.3.9

Load pattern selection (Pr. 14

)

You can select the optimum output characteristic (V/F characteristic) for the
application and load characteristics.

Parameter

Name

Factory

Setting

Setting

Range

Remarks

14

Load pattern
selection

1

0, 1, 2, 3

0: For constant-torque loads
1: For variable-torque loads
2: For vertical lift loads
3: For vertical lift loads

Setting is
enabled when
Pr. 30 = "1".

CAUTION

1. When automatic torque boost control is selected, this parameter setting is

ignored.

2. Pr. 46 "second torque boost" is made valid when the RT signal turns on.

The RT signal acts as the second function selection signal and makes the
other second functions valid.

Related parameters

Automatic torque boost

Pr. 98 "automatic torque boost selection (motor capacity)"

(refer to page 125)

Boost setting

Pr. 0 "torque boost", Pr. 46 "second torque boost" (refer to page 67)

Assignment of RT signal to terminal when second torque boost is used

Pr. 60 to Pr. 63 (input terminal function selection) (refer to page 102)

Forward

rotation

Reverse

rotation

For constant-torque
loads
(e.g. conveyor, cart)

100%

Output

voltage

Base frequency

Output frequency (Hz)

Pr.14=0

For variable-torque
loads
(Fan, pump)

100%

Base frequency

Output frequency (Hz)

Pr.14=1

100%

Base frequency

Output frequency (Hz)

Forward

rotation

Pr.14=2

Pr.0
Pr.46

Pr.14=3

100%

Base frequency

Output frequency (Hz)

Pr.0
Pr.46

For lift

Output

voltage

Output

voltage

Output

voltage

For lift

Reverse

rotation

Boost for forward rotation
...Pr. 0 (Pr.46) setting

Boost for forward rotation
...0%

Boost for reverse rotation
...0%

Boost for reverse rotation
...Pr. 0 (Pr.46) setting