Chapter 4 - troubleshooting, Introduction, Chapter 3 - at commands – Multi-Tech Systems MT128ISA-UV User Manual

Page 26

Advertising
background image

26

Chapter 3 - AT Commands

MT128ISA/PCI

ATS1?

Register 1 is read only, display the ring count

ATS2

Escape code character (S2=43, ASCII “+”)

ATS3

Carriage return character (S3=13, representing a carriage return)

ATS4

Line feed character (S4=10, representing “CTRL J” or the linefeed character)

ATS5

Back space character (S5=8, representing “CTRL H”)

ATS7

Wait for carrier after dial (S7=30 seconds default)

ATS12

Escape code guard time (S12=50 default )

ATS25

Delay to DTR (S25=5 default )

ATS30

Disconnects automatically if no data transmission in n=10 seconds (n=0 to 255; default is S50=0, so it

does not disconnect connection

ATS38

Windows size of HDLC 56K or 64K, 7 default

ATS39

Packet size of HDLC 56K or 64K from 1 to 2048, 2048 default

ATS40

Windows size of V.120, 7 default

ATS41

Packet size of V.120, 256 default

ATS44

Window size of X.75 (Transparent), 2 default

ATS45

Packet size of X.75 (Transparent) from 1—2048, 1024 default

ATS46

Window size of X.75 T.70 NL, 2 default

ATS47

Packet size of X.75 T.70 NL from 1 to 2048, 130 default

ATS50

Window size of X.75 ISO 8208, 2 default

ATS51

Packet size of X.75 ISO 8208 from 128 to 2048, 1024 default

ATS53

Average data flow from 1000 to 7000 bytes (default is 4, which is 4000 bytes). Activates second

channel if average data flow is over 4000 bytes in 10 seconds.

ATS54

Time period from 5 to 20 minutes (default is 5). Disconnects second channel if average data flow is

below n bytes (set by ATS53) in 5 minutes. Only available in MLPPP BOD mode, ATB43.

ATVn

Verbose command

ATV0

Return digit result code

ATV1

Returns word result code ( default )

ATXn

Enable extended result code

ATZ

Reset

+++

Escape command

AT&Cn

Control DCD

AT&C0

Keep always the DCD line ON ( the same as AT&C, default )

AT&C1

DCD line is active if connected

AT&E

Select the line speed in the B channel

AT&E0

64K bps (default)

AT&E1

56K bps

AT&F

Reset registers to factory setting

AT&R

Request to send

AT&S

Handle DSR

AT&S0

Keep DSR always ON ( the same as AT&S )

AT&ZIn*m

Filter the incoming call and accept it when called party number is the same as n and called party

subaddress is the same as m (option, * is the subaddress symbol)

AT&ZOn*m

Make a call with this caller party number (n * m). “n” is the local telephone number, “*” is the sub

address symbol, if needed Command Description (option), and “m” is the sub address (option).

AT#C

Caller ID setting

AT#C?

Display the current Caller ID mode

AT#C0

Disable Caller ID (default)

AT#C1

Enable Caller ID

Advertising
This manual is related to the following products: