CHASSIS INSTALLATION

1. Inspect the ground wire (Figure 6) on the unit and

ensure it is attached to the left side panel. If not, attach

the wire to the panel.

2. Remove the mounting screw from the left hand side of

the existing sleeve (Figure 6). Place the screw through

the eyelet on the unattached end of the ground wire of

the unit and reinsert into its mounting hole.

Ground

Wire

Mounting

Screw

Figure 6

3. Install the 1/2” x 1/2” supplied gasket foam around the

top and two sides of the chassis (Figure 7).

Foam

Figure 7

4. Carefully slide the chassis into the sleeve. Ensure that

the ground wire is not pinched or in the path of the

condenser fan.

5. Fasten the supplied clips to the exposed sides of the

unit using the two #8 x 3/8” blunt sheet metal screws

provided (Figure 8).

Clip

Screw

Figure 8

FRONT PANEL INSTALLATION
Discharge Air Grille

Airflow Direction Change - Optional

If you wish to change the direction of airflow from up to
down, remove the four screws holding the Discharge Air
Grille in place (Figure 9). Drop out the grille and rotate 180°.
Ensure the notches on the grille face up. Replace the grille
and secure in place with the removed screws.

Discharge Air
Grille

Screws

(4 places typ.)

Figure 9