Gas connection

This appliance must be installed
with a separate shut-off valve and a
gas pressure regulator (included).

Both shut-off valve and pressure
regulator must be easily accessible
to the consumer.

This appliance and its individual
shut-off valve must be discon-
nected from the gas supply system
during any pressure testing of that
system.

For USA only

The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
National Fuel Gas Code,
ANSI Z 223.1-1980.

Gas Pressures for USA

Max. Supply Pressure: 1/2 PSI
Manifold pressure:
– Natural gas – 4" water column
– Propane gas – 10" water column

For CDN only

The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
current CAN/CGA B 149.1 and .2
Inst.

Gas Pressures for CDN

Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column

Pressure regulator

A pressure regulator convertible from
Natural to LP Gas is included with this
appliance.

Conversion is carried out by inverting
the regulator cap marked "NAT"/"LP". If
"NAT" is visible then the regulator is set
for Natural and if "LP" is visible then set-
ting is for Liquefied Petroleum Gas (Pro-
pane).

Nominal rating for all types of gas on
the high setting

kW

Btu/hr

Normal burner
Fast burner

1.65
2.70

5630
9212

Nominal rating on the low setting

Type of gas

kW

Btu/hr

Normal burner

Natural gas
LP gas

0.26
0.26

887
887

Fast burner

Natural gas
LP gas

0.45
0.54

1535
1842

Gas connection