Multiquip Submersible Pump ST-3050D User Manual

Page 14

Advertising
background image

PAGE 14 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)

ST-3050D SUBMERSIBLE PUMP — 230/460 VAC VOLTAGE SELECTION

230/460 VAC Voltage Selection

The ST-3050D submersible pump is factory set at 230
VAC. To change the voltage from 230 VAC to 460 VAC,
perform the following:

1.

Remove the four retaining screws that secure the power
cord gland assembly to the pump casing, and pull the 230
VAC female plug (Figure 4) from the pump's cavity.

2.

Un-plug the 230 VAC female plug from the male motor
windings plug and insert the 460 VAC female plug into
male motor windings plug.

3.

Re-install the power cord gland assembly back into the
pump's cavity. Make sure that the gland is seated correctly.
This will prevent any connector pins from bending or
breaking.

4.

Insert the four retaining screws and tighten securely

Figure 4. 230/460 VAC Pump Voltage Selection

Advertising
This manual is related to the following products: