PAGE 16 — ST-3050D — PARTS & OPERATION MANUAL — REV. #1 (11/18/02)

ST-3050D SUB. PUMP/CTRL. BOX — TRANSFORMER WIRING (CB200)

TRANSFORMER 230/460 VOLTAGE SETTINGS

CAUTION:

T

ransformer 230/460 Voltage Settings:

Pump motors are factory set at 230 VAC. The
transformer (Figure 6) of this control box

must

be set to the voltage requirements of the pump
in use. Refer to the attached wiring diagram

located inside the "Control Box" or reference Figures 7 & 8.
Use the two supplied

jumper tabs

to set the transformer to the

required output voltage.

WARNING:

ALWAYS make sure that the transformer is set
to the correct output voltage. Incorrect transformer
output voltage settings can cause severe damage
to the pump.

Figure 6. Transformer AC Voltage Settings (Jumper Tabs)

NOTE

Transformer settings
are for CB 200 Control
Box only!