3 - 36

3. SIGNALS AND WIRING

(e) Only main circuit power supply off (control circuit power supply remains on)

(10ms)

(10ms)

Electromagnetic brake

Dynamic brake

Electromagnetic brake

Dynamic brake

Electromagnetic brake

operation delay time

(Note 2)

(ON)

Forward
rotation

Electromagnetic
brake interlock (MBR)

Servo motor speed

Base circuit

Trouble (ALM)

ON

OFF

ON

OFF

(Note 3)

0r/min

No

Yes (OFF)

Main circuit
power supply

ON

OFF

(Note 1)

15 or more

Note 1. Changes with the operating status.

2. When the main circuit power supply is off in a motor stop status, the main circuit off warning (AL.E9) occurs and the trouble

(ALM) does not turn off.

3. ON: Electromagnetic brake is not activated.

OFF: Electromagnetic brake is activated.