Monessen Hearth Unvented Vent-Free Fireboxes BUF500 User Manual

Page 7

Advertising
background image

61D1013

7

17"

21

1

/

2

"

BUF400: 35

1

/

2

"

BUF400: 20

3

/

8

"

BUF500: 26

3

/

8

"

BUF500: 41

1

/

2

"

Figure 3 - Location of Firebox

MINIMUM HEARTH DIMENSIONS

GENERAL INSTALLATION INFORMATION

Figure 2 - Minimum Hearth Dimensions

Carefully select the best location for installation of your vent-free
firebox. The following factors should be taken into consider-
ation:
• Clearance to side wall, ceiling, woodwork and windows.

See “Clearances/Height Requirements on page 8. Minimum
clearances to combustibles must be maintained.

• Location must not be affected by drafts caused by kitchen

exhaust fans, ceiling fans, return air registers for forced air
furnaces / air conditioners, windows or doors.

• Installation must provide adequate ventilation and combus-

tion air.

• DO NOT INSTALL THIS FIREBOX IN A BEDROOM

OR BATHROOM.

• Location should be out of high traffic or windy or drafty

areas.

• DO NOT INSTALL WHERE CURTAINS, FURNITURE,

CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM FRONT OF HEATER.

• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation air.
• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox must be

kept clear and free from these combustible materials.