Figure 3 - Location of Firebox

MINIMUM HEARTH DIMENSIONS

GENERAL INSTALLATION INFORMATION

Figure 2 - Minimum Hearth Dimensions

Carefully select the best location for installation of your vent-free
firebox. The following factors should be taken into consider-
ation:
• Clearance to side wall, ceiling, woodwork and windows.

See “Clearances/Height Requirements on page 8. Minimum
clearances to combustibles must be maintained.

• Location must not be affected by drafts caused by kitchen

exhaust fans, ceiling fans, return air registers for forced air
furnaces / air conditioners, windows or doors.

• Installation must provide adequate ventilation and combus-

tion air.

DO NOT INSTALL THIS FIREBOX IN A BEDROOM

OR BATHROOM.

• Location should be out of high traffic or windy or drafty

areas.

DO NOT INSTALL WHERE CURTAINS, FURNITURE,

CLOTHING OR OTHER FLAMMABLE OBJECTS ARE LESS THAN 42" FROM FRONT OF HEATER.

• Never obstruct the front opening of the vent-free firebox or restrict the flow of combustion and ventilation air.
• Minimize modifications to existing construction. Refer to Figure 3 below for location suggestions.
• Do not install in the vicinity where gasoline or other flammable liquids may be stored. The vent-free firebox must be

kept clear and free from these combustible materials.