CLEARANCES

AND

HEIGHT REQUIREMENTS

4.

Mantel clearances: The canopy supplied with the unit must
be installed. If a combustible mantel is installed, it must meet
the clearance requirements as shown in Figure 5.

5.

Floor clearance: This inner chamber firebox floor must be installed at least 5" above any combustible flooring mate-
rial, such as carpeting or asphalt tile, which is closer than 14" to the base of the firebox. See Figure 6.

Or
The inner chamber firebox floor may be installed nearer to the floor if a minimum of 14" of noncombustible material

such as slate or marble is installed between the base of the firebox and the combustible flooring. See Figure 7.

Figure 5 - Mantel Clearances

Figure 6 - Minimum Clearance above

Combustible Flooring

Figure 7 - Minimum Clearance above Combustible

Flooring with Non-Combustible Material Installed at

Base of Fireplace

Non-Combustible

Material

5" Minimum

14" Minimum

Can Be

Less than 5"

Non-Combustible

Material