Ms2321/ms2322 scanner design specifications, Ms2321, Ms2322 – Metrologic Instruments StratosH MS2321 User Manual

Page 9

Advertising
background image

5

I

NTRODUCTION

MS2321

/

MS2322

S

CANNER

D

ESIGN

S

PECIFICATIONS

Design Specifications

Operational

Light Source: VLD 650 nm

Peak Laser Power: <2.2 mW

Maximum IR LED Output: 50

μW per IEC 60825-1 measurement procedure

Horizontal Depth of Field: 0 mm - 152 mm (0"- 6") for 0.33 mm (13 mil) Bar Code

Vertical Depth of Field: 0 mm - 216 mm (0"- 8.5") for 0.33 mm (13 mil) Bar Code

Scan Speed: 5840 Scan Lines per Second

No. of Scan Lines: 66 (38 Horizontal / 28 Vertical)

Motor Speed: 4800 / 6000 RPM (Horizontal / Vertical )

Min Bar Width: 0.152 mm (6.0 mil)

Decode Capability: All Standard 1-D Bar Codes, RSS-14, RSS-Expanded, and RSS-14 Limited Bar Codes

System Interfaces: RS232, Aux RS232, RS485

S

, USB, and OCIA

Print Contrast: 35% Minimum Reflectance Difference

No. Characters Read: Up to 80 data characters. Maximum number will vary based on symbology and density.

Beeper Operation: 7 Tones or No Beep; 3 Volume Settings

Blue

Laser ON, Ready to Scan

Indicators (LED):

White

Good Read, Decoding

Mechanical

MS2321 L x W x H: 508 mm (20") Length

290 mm (11.4") Width

181 mm (7.1") Tower Height

MS2322 L x W x H: 420 mm (16.5") Length

292 mm (11.5") Width Counter

181 mm (7.1") Tower Height

Depth (Below Counter): 100 mm (3.9"), All Models

Weight (with Platter): MS2321, 7.48 kg (16.45 lbs.)

MS2322, 6.93 kg (15.25 lbs.)

Electrical

Voltage Supply: 1.5A @ +5V / 1.5A @ +12V

Power: Operating, 14.25 Watts

Standby, 3.25 Watts

Current: Operating, 1A @ 5V / 0.75A @ 12V

Standby, 0.44 A @ 5V / 0.08A @ 12V

DC Transformers: Class II; 5VDC @ 1.5A; 12VDC @ 1.5A

Current Limits on Integrated

Scale and/or Scale Display:

Do not exceed maximum current of 12V @ 0.2A / 5V@ 0.3A

For Regulatory Compliance Information refer to pages 55 - 57.

Environmental

Operating Temperature: 0°C to 40°C (32°F to 104°F)

IP Rating: IP 55

Light Levels: 4842 Lux (450 footcandles)

Storage Temperature: -40°C to 60°C (-40°F to 140°F)

Humidity: 5% to 95% Relative Humidity, Non-Condensing

Contaminants: Sealed to resist airborne particulate contaminants.

Ventilation: None

Required

Specifications are subject to change without notice.