Chapter 4 – AT Commands, S-Registers, and Result Codes

MT5634ZLX, MT5634ZLXI, MT5634ZLX/FE User Guide

19

Command

Options

Function & Description

&P0 (default)

Make=40%, Break=60% for use in North America.

&P1

Make=33%, Break=67% for International use.

&Rn

CTS/RTS option (for non-CTS flow control mode and synchronous mode
only).

&R0 (default)

CTS follows RTS.

&R1

CTS always true.

&Sn

Data Set Ready (DSR) option.

&S0 (default)

DSR always on.

&S1

DSR on during handshake and on-line, off in test mode or idle mode.

&Tn

Self-test commands.

&T0 (then ^ATO)

Terminate test.

&T1

Local analog loopback test.

&T3

Local activated remote digital loopback (RDL) test.

&Vn

View active configuration and stored profile.

&V0

View active file, stored profile #0 and stored phone numbers.

&Wn

Store active profile.

&W0

Save active configuration as user profile #0.

&W1

Save active configuration as user profile #1.

&Yn

Select stored profile on power-up.

&Y0

Recall user profile 0 on power-up.

&Zn=x

Store telephone number n=0 to 3.

x=<string>

See also the dial modifier in ”ATDn” command. The maximum number of
digits per string is 36.

%A

Adaptive Answer Result Code Enable.

%Cn

Data compression option.

%C0

No compression.

%C1 (default)

MNP 5 compression.

\Gn

Set modem port flow control.

\G0 (default)

Disable port flow control.

\G1

Set port flow control to XON/XOFF.

\Jn

Constant DTE speed option.

\J0 (default)

DCE and DTE rates are independent.

\J1

DTE rate adjusts to DCE connection rate after on-line.