Moxa Technologies EDS-518A Series User Manual

Page 30

Advertising
background image

EDS-518A Series User’s Manual

Featured Functions

3-15

V1, V2c Write/Read Community

Setting

Description

Factory Default

V1, V2c
Read/Write
Community

Uses a community string match with a
maximum of 30 characters for
authentication. The SNMP servers access
all objects with read/write permissions
using the community string private.

private

For SNMP V3, there are two levels of privileges for different accounts to access the EDS-518A.
Admin privilege allows access, and authorization to read and write the MIB file. User privilege
only allows reading the MIB file, but does not have authorization to write.

Admin Auth. Type (for SNMP V1, V2c, V3, and V3 only)

Setting

Description

Factory Default

No-Auth

Use admin. account to access objects.
No authentication

No

MD5-
Auth

Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.

No

SHA-
Auth

Provide authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.

No

Admin Data Encryption Key (for SNMP V1, V2c, V3, and V3 only)

Setting

Description

Factory Default

Enable

8-character data encryption key is the
minimum requirement for data encryption
(maximum of 30 characters)

No

Disable

No data encryption

No

User Auth. Type (for SNMP V1, V2c, V3 and V3 only)

Setting

Description

Factory Default

No-Auth

Use admin account or user account to
access objects. No authentication.

No

MD5-Auth

Provides authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum requirement
for authentication.

No

SHA-Auth

Provides authentication based on the
HMAC-SHA algorithms. 8-character
passwords are the minimum requirement
for authentication.

No

Advertising