Moxa Technologies EDS-518A Series User Manual

Page 65

Advertising
background image

EDS-518A Series User’s Manual

Featured Functions

3-50

Radius Server

Setting

Description

Factory Default

IP address or
domain name

The IP address or domain name of the RADIUS server

localhost

Server Port

Setting

Description

Factory Default

Numerical

The UDP port of the RADIUS Server

1812

Shared Key

Setting

Description

Factory Default

alphanumeric
(Max. 40
characters)

A key to be shared between the external RADIUS server
and EDS-518A. Both ends must be configured to use the
same key.

None

Re-Auth

Setting

Description

Factory Default

Enable/Disable

Select to require re-authentication of the client after a
preset time period of no activity has elapsed.

Disable

Re-Auth Period

Setting

Description

Factory Default

Numerical
(60-65535 sec.)

Specify how frequently the end stations need to reenter
usernames and passwords in order to stay connected.

3600

802.1X

Setting

Description

Factory Default

Enable/Disable

Select the option under the 802.1X column to enable
IEEE 802.1X for one or more ports. All end stations
must enter usernames and passwords before access to
these ports is allowed.

Disable

Advertising