Magellan All-In-One Security System V1.0 MG-6060 User Manual

Page 37

Advertising
background image

Paradox Magellan Systems

35

CID#

Reporting Code

Programming
Value

335

Local printer paper out

54

336

Local printer failure

55

337

Expansion module DC loss

56

338

Expansion module low battery

57

339

Expansion module reset

58

341

Expansion module tamper

59

342

Expansion module AC loss

5A

343

Expansion module self-test fail

5B

344

RF receiver jam detect

5C

Communication Troubles - 350 and 360

350

Communication

5D

351

Telco 1 fault

5E

352

Telco 2 fault

5F

353

Long range radio

60

354

Fail to communicate

61

355

Loss of radio supervision

62

356

Loss of central polling

63

357

Long range radio VSWR problem

64

Protection Loop Troubles - 370

370

Protection loop

65

371

Protection loop open

66

372

Protection loop short

67

373

Fire trouble

68

374

Exit error alarm

69

375

Panic zone trouble

6A

376

Hold-up zone trouble

6B

377

Swinger trouble

6C

378

Cross-zone trouble

6D

Sensor Troubles - 380 and 390

380

Sensor trouble

6E

381

Loss of supervision - RF

6F

382

Loss of supervision - RPM

70

383

Sensor tamper

71

384

RF transmitter low battery

72

385

Smoke detector Hi sensitivity

73

386

Smoke detector Low sensitivity

74

387

Intrusion detector Hi sensitivity

75

388

Intrusion detector Low sensitivity

76

389

Sensor self-test failure

77

391

Sensor watch trouble

78

392

Drift compensation error

79

393

Maintenance alert

7A

Open/Close - 400

400

Open/Close

7B

401

Open/Close by user

7C

402

Group open/close

7D

403

Automatic open/close

7E

406

Cancel

7F

407

Remote arm/disarm

80

CID#

Reporting Code

Programming
Value

408

Quick arm

81

409

Keyswitch open/close

82

Remote Access - 410

411

Call back request made

83

412

Success - download access

84

413

Unsuccessful access

85

414

System shutdown

86

415

Dialer shutdown

87

416

Successful upload

88

Access Control - 420 and 430

421

Access denied

89

422

Access report by user

8A

423

Forced access

8B

424

Egress denied

8C

425

Egress granted

8D

426

Access door propped open

8E

427

Access point door status monitor trouble

8F

428

Access point request to exit

90

429

Access program mode entry

91

430

Access program mode exit

92

431

Access threat level change

93

432

Access relay/trigger fail

94

433

Access RTE shunt

95

434

Access DSM shunt

96

Arming - 440 and 450

441

Armed Stay

97

442

Keyswitch armed Stay

98

450

Exception open/close

99

451

Early open/close

9A

452

Late open/close

9B

453

Failed to open

9C

454

Failed to close

9D

455

Auto-arm failed

9E

456

Partial arm

9F

457

Exit error (user)

A0

458

User on premises

A1

459

Recent close

A2

System - 460

461

Wrong code entry

A3

462

Legal code entry

A4

463

Re-arm after alarm

A5

464

Auto-arm time extended

A6

465

Panic alarm reset

A7

466

Service on/off premises

A8

Sounder Relay Disabled - 520

520

Sounder/Relay disabled

A9

521

Bell 1 disabled

AA

522

Bell 2 disabled

AB

523

Alarm relay disabled

AC

524

Trouble relay disabled

AD

Advertising