Instructions for installation (cont’d), Converting the lower element (cont’d) – Maytag HRE2940L User Manual

Page 15

Advertising
background image

15

Instructions for Installation (cont’d)

8. Tighten terminals 2 and 3 to ensure proper electrical con-

nection.

9. Replace the terminal cover on the thermostat making sure

that the locking tabs on the terminal cover are in place.

10. Place the insulation block and pad back in place so that it

completely covers the thermostat and element.

11. Replace the access panel.

12. Complete wiring to the water heater, or if completed,

turn “ON” electric power to the water heater after filling
the tank with water.

Converting the Lower Element
(cont’d)

WARNING

Failure to tighten terminal screws can cause a fire
which can result in DEATH, SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.

WARNING

Make sure the thermostat is flush against the tank,
the terminal cover is in place, and the insulation is
replaced. Failure to do so can result in DEATH, SERI-
OUS BODILY INJURY, OR PROPERTY DAMAGE.

CAUTION

Never use this water heater unless it is completely
full of water. To prevent damage to the tank and
heating element, the tank must be filled with water.
Water must flow from the hot water faucet before
turning “ON” power.

7. The wire removed from terminal 2 has a looped end. It

must remain looped and now be placed (as shown) on top
of the buss bar, over the opening of terminal 2, and secured
using the remaining screw.