Service and maintenance (cont’d), Draining, Thermostat removal/replacement – Maytag HRE2940L User Manual

Page 21

Advertising
background image

21

Service and Maintenance (cont’d)

Draining

The water heater should be drained if being shut down during
freezing temperatures. Also periodic draining and cleaning of
sediment from the tank may be necessary.

1. Before beginning turn “OFF” the electric power supply to

the water heater.

2. CLOSE the cold water inlet valve to the water heater.

3. OPEN a nearby hot water faucet and leave open to allow

for draining.

4. Connect a hose to the drain valve and terminate to an ade-

quate drain or outdoors.

5. OPEN the water heater drain valve to allow for tank

draining.
NOTE: If the water heater is going to be shut down and
drained for an extended period, the drain valve should be
left open with hose connected allowing water to termi-
nate to an adequate drain.

6. Close the drain valve.

7. Follow “Filling the Water Heater” instructions in the

“Instructions for Installation” section.

8. Turn “ON” power to the water heater.

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water heater,
make sure the electrical supply to the water heater
is turned “OFF”. Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.

CAUTION

Never use this water heater unless it is completely
full water. To prevent damage to the tank and heat-
ing element, the tank must be filled with water.
Water must flow from the hot water faucet before
turning “ON” power.

Thermostat
Removal/Replacement

1. Turn “OFF” the electrical power to the water heater at the

junction box.

2. Remove the access panel and the insulation block and pad.

3.

Lift out the tab as shown below to unclip the terminal cover
from the thermostat. The terminal cover can now be
removed from the thermostat.

WARNING

HAZARD OF ELECTRICAL SHOCK! Before removing
any access panels or servicing the water heater,
make sure the electrical supply to the water heater
is turned “OFF”. Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE.

Lift out tab to unclip
terminal cover from
thermostat.

UPPER OR LOWER

THERMOSTAT WITH

HIGH LIMIT

LOWER THERMOSTAT
WITHOUT HIGH LIMIT

4. Remove the two wires attached to the thermostat.

5. Remove the thermostat from behind the thermostat bracket.

6. Disconnect wires from thermostat and slide out of the bracket.

7. Place the new lower thermostat in the bracket making sure it

fits firmly against the tank.

8. Attach the wires to the new thermostat.

NOTE: Some of the terminals may require straight-in
wiring through an eye-opening. If wires are now looped, re-
cut and strip wire

3

8

to a straight length and insert.

Advertising
This manual is related to the following products: