Troubleshooting guide – Metrologic Instruments MS9535 User Manual

Page 32

Advertising
background image

28

T

ROUBLESHOOTING

G

UIDE

The following guide is for reference purposes only. Contact a Metrologic
representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited
warranty terms.

Symptoms Possible

Causes

Solution

No LEDs, beep
or laser -

Scanner in Cradle

No power is being
supplied from cradle
to scanner

Check transformer, outlet and
power strip. Make sure the cable
is plugged into the cradle properly.


No LEDs, beep,
or laser -

Scanner out of
Cradle

Internal battery not
supplying power to
scanner

Place the scanner into cradle to
recharge the battery.


Scanner’s white
LED locks up
after first scan,
and razz twice

Communication is not
established between
scanner and cradle

Establish communication between
scanner and cradle before
scanning a normal bar code


Scanner scans,
but white LED
locks up at one
scan and razz
twice

The distance between
scanner and cradle is
beyond the 10-meter
operation range

Bring the scanner back into the
10-meter communication range
from the cradle.


2 Beeps with
alternately
flashing LEDs
on Power up

Possible ROM failure

Flash ROM Upgrade Required

3 Beeps on
power up

Non-volatile RAM
failure

Contact a Metrologic
Representative, if the unit will not
hold the programmed
configuration.

Continuous razz
tone on power
up

RAM or ROM failure

Contact a Metrologic
Representative, if the unit will not
function.

Razz tone and
blue LED flash
at power up

VLD failure

Contact a Metrologic
Representative


Razz tone, blue
and white LEDs
flash at power
up

Scanning mechanism
failure

Contact a Metrologic
Representative