tRouBLeShootING

W

ARNING

turn appliance oFF and allow to cool before
servicing.
only qualified service person should service
and repair the heater.

oBSeRVeD pRoBLeM

Spark ignitor will not light the
pilot after repeated pressing of
spark ignitor.

Pilot will not stay lit.

Burner will not light when valve
and burner switch are both on.

Glass fogs up

Blue flames

Sooting

poSSIBLe cAuSe

1. Battery needs replacing
2. Defective ignitor

3. Misaligned spark electrode

4. Bad wire.

1. Defective thermocouple.

Loose thermocouple

2. Air in gas line
3. No gas

1. Defective switch

2. Defective thermopile

3. Thermostat set too low/defective

1. Normal condition

1. Normal during start up

1. Flame impingement

ReMeDy

1. Replace battery
2. Check connections to ignitor. Replace

ignitor if ignitor connections are good,
but there is no spark.

3. Check for spark arcing from the elec-

trode to pilot. Adjust and retighten.

4. Replace with new wire.

1. A. Check for proper connection of

thermocouple to rear of valve.

B. Check thermocouple output.
2. Bleed line. Contact dealer
3. Check shutoff valve and gas supply

(LPG tank)

1. Check switch connections. Jump

wires at switch.

2. A. Check thermopile output.
B. Check connections to valve. Con-

tact dealer.

3. Turn up thermostat to start unit.

Check thermostat connections.

1. Allow appliance to warm up. Glass

will clear. Additives in the gas may
dirty glass. Clean glass when cool.

1. Flames will yellow as appliance

heats up. Adjust rock wool placement
per instructions.

1. Check log position. Open shutters to

increase primary air.