Uv36 vent-free firebox, Install optional outside air kit, Installation instructions – Majestic Appliances UV36 User Manual

Page 8

Advertising
background image

8

UV36 Vent-Free Firebox

20007446

T234

finishing w/facing

2/04

Finished Wall

Noncombustible

Decorative Covering

Stud

Header

Must be enclosed with a

noncombustible material.

T234

6a Wallboard with Marble, Slate or Tile Facing

T235

finishing w/facing,

and mantel

2/04

Finished Wall

Noncombustible

Decorative Cover-

ing

Stud

Header

Must be enclosed with a

noncombustible material.

The bottom mantel projection must be located a mini-

mum of 9” above the fireplace opening. (Fig. 5b)

T235

6c Wallboard with Facing and Mantel

T236

brick or stone

facing

2/04

Finished Wall

Stud

Header

6b Brick or Stone Facing

T236

Brick or

Stone Facing

Steel Lintel*

T237

facing not flush

2/04

6d Wallboard with Facing-Not Flush

Brick or

Stone Facing

Finished Wall

Stud

Header

Steel Lintel*

T237

*Brick or stone facings lid up on the face of the fireplace must be

sealed to it with a steel lintel. Attach the lintel to the fireplace face

with sheet metal screws and seal it with a heat resistant sealer.

The projecting portion of the lintel should be imbedded in a mortar

joint or mortared to the bottom of the facing. The lintel acts as a

support and a firestop.

Fig. 5 Finishing options.

Install Optional Outside Air Kit

The AKU3 Outside Air Kit can be installed to bring com-
bustion air to the heated room air. The air that is drawn
into the heated room air from outside the home or un-
heated area helps relieve the pressure in the home.
The duct termination should be located so it is exposed
to an out-of-doors opening at least 100 square inches.
If the duct termination must be located in a crawl space
or basement, be sure the termination area has 100
square inches of ventilation opening to outside air.
The duct termination must be located so it does not
compete for air flow with exhaust fans, gas vent hoods
or other air consuming devices or appliances. It must
not be obstructed by rafters, insulation materials or
other obstructions. The less restrictive the air supply,
the better the outside air kits will perform.
It is good practice to protect your hands and eyes
during installation by wearing work gloves and safety
glasses.
CAUTION: Do not install termination into a garage
or other area that could contain flammable liquids
or fumes, or into an attic space.

Installation Instructions

Determine the location of the fireplace as described
in the fireplace installation manual. Then plan location
of the duct termination and the route of the duct run
between the fireplace and the duct termination.
Duct run must be limited to a maximum distance of 40’
(12.2m) from the fireplace pipe collar to duct termina-
tion. This will provide the least restriction to air flow. No
more than four (4) 90° elbows can be used. Duct run
may be horizontal, vertical, inclined or any combina-
tion of these. (Fig. 7) You are now ready to install the
Outside Air Kit.
1. Remove the screws retaining the outside air cover-

plate, if provided. (Located on the left side of front
open units, on backside of multisided units.) Discard
coverplate. (Fig. 8)

2. Secure the inlet collar assembly to the outer casing

with four screws (not provided). (Fig. 9)

3. Slide the duct over the collar and attach the duct

to the collar using the plastic tie straps or three (3)
screws (screws not provided). Continue attaching
the ducting together using three (3) screws at each
joint until you have installed sufficient duct to arrive
at your duct termination locations.