Uv36 vent-free firebox – Majestic Appliances UV36 User Manual

Page 9

Advertising
background image

9

UV36 Vent-Free Firebox

20007446

FP1060

AKMST installation

7/6/00 djt

Ceiling

Attic

Duct

Duct

Termination

40’ Max.

Duct Run

Soffit Termination

Exterior Wall

Rain Cap

Duct Termination

40’ Max. Duct Run

Duct

Exterior Wall Termination

FP1060

Fig. 7 Typical outside air installations.

KT143

AKU cover plate

9/5/00 djt

Cover Plate

KT143

Fig. 8 Remove outside air cover plate and discard, retain
screws.

4. At the termination end, install the duct termination.

This should be installed from the outside of the
home. Cut a hole in the desired location approxi-
mately 4¹⁄₂” (114mm) in diameter, caulk around the
hole, and slide the termination through the opening
from outside the home. The termination/rain cap

should be caulked around its perimeter to assure a
tight seal. The rain cap opening should be positioned
downward. (Fig. 10)

The Outside Air Kit is now installed and ready for use.

KT145

AKU reinstall

cover plate

9/6/00 djt

KT145

Fig. 9 Secure the inlet collar assembly.

FP1061

AKMST

rain cap

7/6/00 djt

Caulking

Duct Ter-
mination

Rain
Cap

Wall

FP1061

Fig. 10 Caulk and install duct termination/rain cap in place.

Operating Precautions and Instructions

Operation is automatic. A slight negative pressure inside
the house will open the barometric flapper valve.

Periodically inspect the duct termination for any block-
age. Correct if necessary.