Purpose:

Measuring

Instrument
Test Point

Measuring

Range
Input Signal

Ext. Trigger

Input Terminal

Symptom:

Purpose

Measuring

Instrument

Test Point

Measuring

Range
Input Signal

Ext. Trigger

Input Terminal

Symptom:

MODELS: WS-48513 / WS-48613 / WS-55513 / WS-55613 / WS-55813 / WS-65513 / WS-65613 / WS-65713 /

WS-65813 / WS-73513 / WS-73713

[Video Circuit]

Oscilloscope

JA pin 28 & JA pin 37

JB pin 5

------

------

Color Bars

Video

To match the sub picture color to that of the main picture.

Main and sub pictures colors differ.

1. Supply an NTSC signal to an External Video Input.
2. Select the NTSC signal as the source for both the main and sub pictures.
3. Connect an oscilloscope to connector JA pin 28 (Main Pr).
4. Activate the Adjustment mode.
5. Select Item “24 SCLR” in the Main Matrix Function.
6. Adjust data so the PR signal is 0.71 Vp-p max. - 0.66 Vp-p min

(If it cannot be adjusted within this range, set to the lower value)

7. Connect an oscilloscope to connector JA pin 37 (Sub PR).
8. Select item “24 SCLR” in the Sub Matrix Function.
9. Adjust so Sub PR = Main PR.

3. Main/Sub Color Level

CIRCUIT ADJUST MODE

Activate …….. MENU-0-3-5-7
Function …...………..AUDIO
Item No. ……….…….VIDEO
Adjust Data ….…….ADJUST
Save Data …. ………ENTER
Exit …………..MENU (twice)

To set the cutoff point for all three CRTs.

Monochrome has a color tint, or incorrect brightness.

[CRT Circuit]

4. CRT Cutoff

Oscilloscope

TP6R, TP6G, TP6B

------

50V/Div. 2msec/Div.

None

Video Input

Note: Use the Expand mode (full screen)

1. Select an External Input with no signal.
2. Enter the Adjustment Mode, VC Function.
3. Press “1”, automatically blanks the screen and sets COL to 0.

Note: If the screen goes blue, turn off Video Mute.

4. Set the data to the values given in the table below.
5. Connect the oscilloscope to TP6R.
6. Adjust the Red Screen VR so the black level is 175V, as shown below, or

178V ±1VDC using an DC Voltmeter.

7. Repeat Steps 4 and 5 to set the Blue and Green Screen VRs, using

TP6G and TP6B.

Note: White Balance must be performed

after this adjustment.

CIRCUIT ADJUST MODE

Activate …….. MENU-0-3-5-7
Function …...………..AUDIO
Item No. ……….…….VIDEO
Adjus t Data ….…….ADJUST
Save Data …. ………ENTER
Exit …………..MENU (twice)

VC Function

Item

Abbr.

Setting

1

SBRT

24

2

SCT

42

3

SCON

9

4

RDRH

31

5

GDR

42

6

BDRH

40

7

CTRH

31

8

CTGH

43

9

CTBH

25

Advertising