MITSUBISHI ELECTRIC WS-48513 User Manual

Page 46

Advertising
background image

Page 46

Purpose:

Measuring

Instrument
Test Point

Measuring

Range
Input Signal

Ext. Trigger

Input Terminal

Symptom:

Purpose

Measuring

Instrument

Test Point

Measuring

Range
Input Signal

Ext. Trigger

Input Terminal

Symptom:

MODELS: WS-48513 / WS-48613 / WS-55513 / WS-55613 / WS-55813 / WS-65513 / WS-65613 / WS-65713 /

WS-65813 / WS-73513 / WS-73713

To improve edge focus.

Poor focus at the edges of the screen.

[Focus Circuit]

9. Dynamic Focus Preset

-----

-----

------

-----

Monoscope

Video Input

1. Supply a Monoscope signal to a Video Input
2. Activate the Convergence Mode.
3. Select the DF Function under the Conv. Coarse Mode.
4. Set Items “0 DFH” and “1 DFV” to the data values given in the DF Table.
5. Press “6” to activate CONV-MISC
6. Set “0 FPHS” and “1 DPHS” to data values given in the CONV-MISC Table.
5. Exit the Conv. Mode.

-----

------

------

-----

Monoscope

Video Input

Poor focus

Note: This adjustment must be done before Electrostatic Focus. Perform this

adjustment for RED, GREEN, and BLUE monochrome pictures.

1. Supply a VIDEO signal (Monoscope).
2. Cover the Red and Blue Lens (producing a green raster).
3. Adjust the Green Lens for best focus at the center of the Monoscope pattern.

Note: Attach a white paper to the
screen center. During adjustment,
observe the picture on the screen
from inside for easier adjustment.

4. Repeat Steps 2 and 3 for the Red

and Blue monochrome pictures.

[Video Circuit]

10. Lens Focus

To set the Lens position for optimum focus.

CONVERGENCE MODE

Activate ……..MENU-0-3-5-9
Misc. ……………….……"6"
Coarse………………..…."5"
Fine ……………………..."4"
Color (R,G or B)……AUDIO
Item No………….…..VIDEO
Adjust/Move……….ADJUST
Cursor Toggle….…..ENTER
Save & Exit…..MENU (twice)

DF
(MENU-0-3-5-9-5)

Item Abbr. Data

1

DFH

-300

2

DFV

-50

CONV MISC
(MENU-0-3-5-9-6)

Item Abbr. Data

9

DPHS

0

10

DOFS

21

Advertising
This manual is related to the following products: