8. dc/cv mig volt-ampere curves, 1. installing welding generator – Miller Electric Trailblazer Pro 350 User Manual

Page 18

Advertising
background image

OM-4401 Page 14

3-8.

DC/CV MIG Volt-Ampere Curves

203 112

Volt-ampere curves show minimum
and maximum voltage and amper-
age output capabilities of unit.
Curves of other settings fall be-
tween curves shown.

0

5

10

15

20

25

30

35

40

45

0

100

200

300

400

500

600

DC AMPERES

DC VOL

TS

SECTION 4 – INSTALLATION

install1 10/00 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854

Y

Do not weld on base. Weld-
ing on base can cause fuel
tank fire or explosion. Bolt
unit down using holes pro-
vided in base.

Y

Always securely fasten
welding generator onto
transport vehicle or trailer
and comply with all DOT and
other applicable codes.

Y

Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.

1

Generator Base

2

Metal Vehicle Frame

3

Equipment Grounding
Terminal

4

Grounding Cable

Use #10 AWG or larger insulated
copper wire.

Y

If unit does not have GFCI re-
ceptacles, use GFCI-
protected extension cord.

1

2

Electrically bond genera-
tor frame to vehicle frame
by metal-to-metal contact.

GND/PE

3

4

2

OR

OR

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

18 in

(460 mm)

OR

Movement

Airflow Clearance

Location

Grounding

Y

Do not lift unit from end.

4-1.

Installing Welding Generator

Advertising