Troubleshooting dryer, Dryer operation, Dryer will not run – Maytag W10196552A User Manual

Page 11: No heat, Unusual sounds, Timer does not noticeably advance, Dryer results, Warning

Advertising
background image

11

TROUBLESHOOTING DRYER

First try the solutions suggested here or visit our website and reference FAQs (Frequently Asked Questions)

to possibly avoid the cost of a service call...

In U.S.A. www.whirlpool.com/help - In Canada www.whirlpool.ca.

Dryer Operation

Dryer will not run

Has a household fuse blown, or has a circuit breaker tripped?

There may be 2 fuses or circuit breakers for the dryer. Check that

both fuses are intact and tight, or that both circuit breakers have

not tripped. Replace the fuse or reset the circuit breaker. If the

problem continues, call an electrician.

Is the correct power supply available? Electric dryers require

240 volt power supply. Check with a qualified electrician.

Was a regular fuse used? Use a time-delay fuse.

Is the dryer door firmly closed?

Was the PUSH TO START dryer button firmly pressed?

No heat

Has a household fuse blown, or has a circuit breaker tripped?

The drum may be turning, but you may not have heat. Electric

dryers use 2 fuses or circuit breakers. Replace the fuse or reset
the circuit breaker. If a problem continues, call an electrician.

For gas dryers, is the valve open on the supply line?

Unusual sounds

Has the dryer had a period of non-use? If the dryer hasn’t been

used for a while, there may be a thumping sound during the first

few minutes of operation.

Is a coin, button, or paper clip caught between the drum and

front or rear of the dryer? Check the front and rear edges of the

drum for small objects. Clean out pockets before laundering.

Is it a gas dryer? The gas valve clicking is a normal operating
sound.

Are the four legs installed, and is the dryer level front to back

and side to side? The dryer may vibrate if not properly installed.

See the Installation Instructions.

Is the clothing knotted or balled up? When balled up, the load
will bounce, causing the dryer to vibrate. Separate the load items

and restart the dryer.

Timer does not noticeably advance

Is the dryer set to Timed or Air Dry?

The timer moves slowly and continuously for the timed setting.

Is the dryer set to Automatic Drying?

The timer moves only when the clothing is mostly dry.

Dryer Results

Clothes are not drying satisfactorily, drying times are too long,

or load is too hot

Is the lint screen clogged with lint? Lint screen should be

cleaned before each load.

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death
or fire.

Is the exhaust vent or outside exhaust hood clogged with lint,

restricting air movement? Run the dryer for 5-10 minutes. Hold
your hand under the outside exhaust hood to check air

movement. If you do not feel air movement, clean exhaust

system of lint or replace exhaust vent with heavy metal or

flexible metal vent. See the Installation Instructions.

Are fabric softener sheets blocking the grille? Use only one

fabric softener sheet, and use it only once.

Is the exhaust vent the correct length? Check that the exhaust

vent is not too long or has too many turns. Long venting will
increase drying times. See the Installation Instructions.

Is the exhaust vent diameter the correct size? Use 4" (102 mm)

diameter vent material.

Is the dryer located in a room with temperature below

45ºF (7ºC)? Proper operation of dryer cycles requires

temperatures above 45ºF (7ºC).

Advertising