Signals and wiring – MITSUBISHI ELECTRIC J2-JRSERIES MR-J2-03A5 User Manual

Page 55

Advertising
background image

3 - 30

3. SIGNALS AND WIRING

(3) Speed setting in speed control mode

(a) Speed command and speed

The servo motor is run at the speed set in parameter No. 8 (internal speed command 1) or at the
speed set in the applied voltage of the analog speed command (VC). A relationship between analog
speed command (VC) applied voltage and servo motor speed and the rotation directions determined
by the forward rotation start signal (ST1) and reverse rotation start signal (ST2) are as in (a), (1) in
section 3.4.2.
Generally, make connection as shown below:

SD

1k

2k

Servo amplifier

Japan Resistor
RRS10 or equivalent

LG

VC

P15R

SG

SP1

When a precision speed command is required, refer to (a), (1) in section 3.4.2

(b) Speed selection 1 (SP1) and speed command value

Use speed selection 1 (SP1) to select between the speed set by the internal speed command 1 and
the speed set by the analog speed command (VC) as indicated in the following table:

(Note) External Input Signals

SP1

Speed Command Value

0

Analog speed command (VC)

1

Internal speed command 1 (parameter No. 8)

Note. 0: SP1-SG off (open)

1: SP1-SG on (short)

The speed may also be changed during rotation. In this case, it is increased or decreased according
to the value set in parameter No. 11 or 12.
When the internal speed command 1 is used to command the speed, the speed does not vary with
the ambient temperature.

(c) Speed reached (SA)

As in Section 3.4.2 (2).

Advertising