6 delay times – Marmitek MS9770 User Manual

Page 19

Advertising
background image

19

MS9470/MS9770/MS9970

5.6 DELAY TIMES

ARMING
When arming the security system by means of the remote controls KR21 or SH624 in the ARM AWAY mode, the system will
arm with a instantaneously (factory default). In case you want to arm the system delayed, you can program the base station
for a delay. (N.B.: Arming the system by means of the ARM AWAY button on the base station, always will result in a delayed
arming of the system).

ALARM SENSORS
When the security system is armed, sensors can activate the system either instantaneously or with a delay. This depends on
the settings of the SC2800 base station and the switch setting of the sensors. Refer to the list below for a complete
overview.
Every time you press a key you hear a short confirmation beep.

1. Set the mode switch to the INSTALL position: All indicators of occupied zones come on

2. Key in your 4 digit PIN code (factory default [0000] refer to 5.8)

3. Press key number 5

4. Press ENTER

5. Press 0 for instantaneous alarm

or
Press 1 for delayed alarm

6. Reset the mode switch to the RUN 1 or RUN 2 position: Zone indicators go out

OVERVIEW DELAY TIME:

SC2800 base station operation “instantaneous alarm”
Arming of the system with remote controls:

Instantaneous

Arming of the system with ARM AWAY button of base station:

Delay of one minute

Arming of the system with ARM HOME button of base station:

Instantaneous

Alarm activation by a DS10 door/window contacts:

Instantaneous when switch is in MIN position,
30 seconds when in MAX position

Alarm activated by an MS10 motion sensors:

Instantaneous

SC2800 base station operation “delayed alarm”
Arming of the system with remote controls:

Delay of one minute

Arming of the system with ARM AWAY button of base station:

Delay of one minute

Arming of the system with ARM HOME button of base station:

Delay of one minute

Alarm activation by a DS10 door/window contacts:

Instantaneous when switch is in MIN position,
30 seconds when in MAX position

Alarm activated by an MS10 motion sensors:

Delay of 30 seconds