DCA400 SerieS — Fuel return line kit inStruCtionS p/n 35499 — rev. #0 (01/26/11) — pAge 3
4. Disconnect drain hose from trailer return port. See
Figure6.
Figure 6. Disconnect Drain Hose
5. Removefittingsfromtrailerreturnport.Retainthe90º
fitting,anddiscardtheothers.SeeFigure7.
Figure 7. Remove Trailer Return Port Fittings
Drain
Disconnect
Drain Hose
Trailer
Return
Port
Trailer
Return Port
Remove
Fittings
Retain
90º Fitting
inStAll neW trAiler return port FittingS
RefertoFigure8.
Figure 8. New Trailer Return Port Fittings
1. InstallItem3,teefitting,intotrailerreturnport.
2. InstallItem2,straightfitting,intotherightsideofthe
teefitting.
3. Installexisting90ºfittingintoItem2.Connecttodrain
hose.
4. InstallItem4,straightfitting,intotheleftsideofthetee.
Existing 90º
Fitting
Drain
Hose
2
4
3
NOTICE
Applypipesealanttoallfittings.