Multiquip Generator DCA400 User Manual
Page 4
Advertising

DCA400 SerieS — Fuel return line kit inStruCtionS p/n 35499 — rev. #0 (01/26/11) — pAge 4
inStAll neW return extenSion hoSe
RefertoFigure9.
1. Connect Item 6, return extension hose, to item 4.
Securewithclamp,Item5.
2. InstallItem7,straightfitting,betweenextensionhose
andexistingenginereturnhose.Securewithclamps.
Figure 9. New Return Extension Hose
3. Installspiraltubing,Item10,aroundreturnextension
hose.Securewithcableties,Item9.SeeFigure10.
5
5
5
7
6
Engine
Return Hose
4
Figure 10. Spiral Tubing
inStAll neW vent hoSe
1. ConnectItem8,venthose,togeneratorpick-upportand
returnport.Securewithclamps,Item5.SeeFigure11.
Figure 11. Vent Hose
9
9
10
5
5
8
Pick-Up
Port
Return
Port
Advertising