NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Note: The gas valve ON/OFF switch is shown in
Figure 18. It is integral with the gas valve and
should be set to the ON position.

10. If wall-mounted ON/OFF switch or thermo-

stat is to be used, mount it in a convenient
location on a wall near the fireplace.

11. If the wall-mounted ON/OFF switch is to be

used, wire it to the the low voltage circuit
as shown in

Figure 18.

Note: The supplied 15 feet of 2 conductor wire
has one end of each conductor connected to
the gas valve circuit and the other end of each
conductor placed loose inside the lower com-
partment of the unit.

12. After wiring is complete, reinstall the out-

let receptacle; install the field-provided
the metal junction box cover plate; rein-
stall the modesty panel.

OUTLET RECEPTACLE INSTALLATION

Figure 17

EBST-2, EBPF-2

AND EBCL-2 OUTLET RECEPTACLE SHOWN.

EBCR-2 HAS THE OUTLET RECEPTACLE LOCATED IN

THE LEFT CORNER OF THE UNIT

EBBAY OUTLET RECEPTACLE LOCATED IN

THE REAR LEFT CORNER OF THE UNIT

VIEW OF RIGHT BOTTOM CORNER OF UNIT

OUTLET RECEPTACLE

JUNCTION BOX

OUTLET RECEPTACLE

BOX SECURING SCREW

CABINET

RIGHT SIDE

PANEL

FIREBOX BOTTOM

IMPORTANT: Ground supply wire must
be connected to the green wire attached
to the outlet receptacle's green ground
screw. See

Figure 18. Failure to do so

will result in a potential safety hazard.
The appliance must be electrically
grounded in accordance with local codes
or, in the absence of local codes, the
National Electrical Code, ANSI/NFPA 70-
(latest edition). (In Canada, the current
CSA C22-1 Canadian Electrical Code.)

Step 5. CONNECTING GAS LINE

Make gas line connections. All codes require a
shut-off valve mounted in the supply line.
Figure 19 on page 12 illustrates two methods
for connecting the gas supply. The flex-line
method is acceptable in the U.S., however,
Canadian requirements vary depending on lo-
cality. Installation must be in compliance with
local codes.

Figure 18

1. If any of the original wire as supplied must be replaced,

1.

it must be replaced with

Type AWM 105

°

C – 18 GA.

wire.

2. 120V, 60Hz – Less than 3 amps.

BK

Transf.

120 V.

24 V

Factory Wired

Field Wired

BL

Electronic Wiring Diagram (Honeywell)

R

WT

BL

W

Gas Valve

B

APPLIANCE-MOUNTED ON/OFF SWITCH

R

IGNITER

PILOT

ASSEMBLY

BK

Schematic Representation Only

*ON/OFF Switch (Integral

with Gas Valve)

**OPTIONAL WALL SWITCH

OR OPTIONAL THERMOSTAT

OR OPTIONAL REMOTE

RECEIVER

*Leave the ON/OFF switch, which is integral

with the gas valve, in the ON position.

**Turn the appliance-mounted ON/OFF burner control switch to

the OFF position if an optional control switch is installed.

LIMIT SWITCH

WT

G

Junction Box

White

Green

Red

Black

Neutral
Side of
Receptacle

Tab Intact

Green
Ground
Screw

Hot
Side of
Receptacle

Tab
Broken