3 Remote Configuration

16

MultiModemZPX User Guide

To Change the Remote Escape Character

To further improve security, you can change a remote modem’s remote configuration escape character ei-
ther locally or remotely. The remote configuration escape character is stored in register S9. The factory
default is 37, which is the ASCII code for the percent character (%). Setting S9 to 0 (zero) disables remote
configuration entirely.

CAUTION:

If you do this remotely, you won’t be able to change it back remotely.

1.

Establish a remote configuration link with the remote modem as described in “Basic Procedure.”

2.

Type ATS9=n, where n is the ASCII code for the new remote configuration escape character, and

then press E

NTER

.

3.

Save the new value by typing AT&W and pressing E

NTER

.

4.

Type ATO and press E

NTER

to exit remote configuration.