101487

Pump Pressure
Adjustment

1. Remove pressure gauge

plug from filter end cover.

2. Install accessory pressure

gauge (part number
HA1180).

3. Start heater (see Operation,

page 7). Allow motor to
reach full speed.

4. Adjust pressure. Turn relief

valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
Set pump pressure at 4.9
psi.

5. Remove pressure gauge.

Replace pressure gauge
plug in filter end cover.

Nozzle

1. Remove upper shell (see

page 10).

2. Remove fan (see page 14).
3. Remove spark plug wire

from spark plug.

4. Remove spark plug from

burner head using 13/16"
open-end wrench.

5. Loosen flare nut using

3/4" open-end wrench.
Push fuel tube down.

6. Remove air line hose from

burner head.

7. Remove three screws

using 5/16" nut-driver and
remove burner head from
combustion chamber.

8. Place burner head into vise

and lightly tighten.

9. Carefully remove nozzle

from burner head using
5/8" socket wrench (see
Figure 13).

10. Blow compressed air thru

face of nozzle. This will
free any dirt in nozzle area.

11. Inspect nozzle seal for

damage.

Figure 12 - Removing Burner Head

Spark
Plug

Combustion
Chamber

Fuel Tube

Flare Nut

Burner Head

Screw

Spark Plug
Wire

Air Line Hose

150 PRESSURE ADJUSTMENT Plug

PF

Figure 10 - Pressure Gauge Plug Removal

Pressure
Gauge
Plug

Relief
Valve

150 PRESSURE ADJUSTMENT

PF

Pressure
Gauge

Figure 11 - Adjusting Pump Pressure