UNINET IMAGING INC. • MINOLTA

®

MAGICOLOR 5430 CARTRIDGE REMANUFACTURING INSTRUCTIONS

SEPARATING THE DRUM UNIT
5. The drum unit (top) and developer unit (bottom) are joined
together.

6. Locate the gear train side of the drum unit.

Remove the OPC contact (highlighted).

Now remove the gear train directly behind it. Note the position-
ing of the gears. One of the gears is not removable.

7. After removing he gears, release the two screws that hold the
drum axle plate in place.

Release the compression spring that is connected to the devel-
oper unit beneath.

Slide the drum axle plate out.

8. Drum axle plate removed.