Learances, Residential installation – Monessen Hearth BWB400 User Manual

Page 45

Advertising
background image

5

NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER. NON-COMBU

NOTE: COMBUSTIBLE MATERIALS SHOULD NOT BE INSTALLED BELOW TOP SPACER. NON-COMBUSTIBLE MATERIALS
SUCH AS BRICK OR TILE MAY BE USED TO TRIM FACE OF THE FIREPLACE BUT SHOULD NOT C

SUCH AS BRICK OR TILE MAY BE USED TO TRIM FACE OF THE FIREPLACE BUT SHOULD NOT COVER ANY PORTION OF THE

OVER ANY PORTION OF THE

LOUVERED PANEL OR COOL AIR INLET. COMBUSTIBLES MUST NOT OVERLAP THE BLACK PAINT

LOUVERED PANEL OR COOL AIR INLET. COMBUSTIBLES MUST NOT OVERLAP THE BLACK PAINTED FACE OF FIREPLACE.

CAUTION: DO NOT BLOCK AIR INLETS OR OUTLETS.

FIREPLACE - MODEL SCF42A OR SCF42AI SHOWN

RESIDENTIAL INSTALLATION

RESIDENTIAL INSTALLATION

TO COMBUSTIBLES MODEL:

CHIMNEY (2" MIN. AIR SPACE

44 1/2"

FRAMING

DIMENSION

FRAMING DIMENSIONS

FRONT - TO BACK

21 1/2"

COMBUSTION AIR

ASSEMBLY MODEL AK4

FLEXIBLE DUCT

TYPE FP-4-U

NAIL TO FRAMING MEMBERS

COOL AIR INLET (SEE CAUTION)

GD42B/GD42PB GLASS
DOOR ACCESSORY

WARM AIR OUTLET
(SEE CAUTION)

GALVANIZED METAL STRIP

TOP SPACER

S12 (1 FT. PIPE)

S18 (18 IN. PIPE)

S36 (3 FT. PIPE)
S48 (4 FT. PIPE)

SEE NOTE

FIRESTOP-MODEL SF

(REQUIRES 14 1/2 X 14 1/2 OPENING)

1 3/4" MIN. AIR SPACE TO COMBUSTIBLES)

STORM
COLLAR

ROOF FLASHING

MODEL 612

ROUND CHIMNEY CAP

MODEL SC

(BOTTOM OF FIREPLACE)

(FLUE OUTLET HEIGHT)

44"

FRAMING

DIMENSION

14 FT. = MIN. HEIGHT (NO OFFSETS)
14 FT. = MIN. HEIGHT (2-30˚ ELBOWS)

ELBOWS)

21 FT. = MIN. HEIGHT (4-30˚ ELBOWS)

ELBOWS)

86 FT. = MAX. HEIGHT (CHIMNEY
SUPPORT EVERY 30 FT.)

F

IGURE

1

6

C

LEARANCES

53D9032. Rev 1 03/03