Nstallation, 31 f, 30 f – Monessen Hearth BWB400 User Manual

Page 67

Advertising
background image

27

FINISHED WALL

FINISHED WALL

FRAMING

FRAMING

1/4"

INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPL

INSTALLATION OF NON-COMBUSTIBLE FACING MATERIALS TO THE FRONT FACE OF THE FIREPLACE

COMBUSTIBLE FRAMING

MEMBERS FACING MATERIAL

TO TOP OF SPACERS.

CAUTION:
DO NOT COVER
OR RESTRICT SIDE VENT
AREAS WITH SURROUND
OR TRIM MATERIALS.

USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP OF SPACERS.

NON-COMBUSTIBLE

FACING MATERIAL

FIREPLACE FACE

STEEL LINTEL
(OPTIONAL)

WARNING:
THE SPACE BETWEEN THE
FACE OF THE FIREPLACE
AND THE NON-COMBUSTIBLE
FACING MATERIAL MUST BE
SEALED. FAILURE TO
PROPERLY SEAL THIS CRACK
CAN CAUSE A POSSIBLE FIRE
HAZARD AND WILL VOID THE
WARRANTY.

SCREENED OPENING

SCREENED OPENING

OF FIREPLACE

OF FIREPLACE

4"

4"

(REF.)

(REF.)

EXTEND LINE FROM OPPOSITE REAR OF

EXTEND LINE FROM OPPOSITE REAR OF
FIREBOX THRU A POINT 4" IN FRONT OF

FIREBOX THRU A POINT 4" IN FRONT OF
FIREPLACE FACE, AND 1" OUTSIDE OF

FIREPLACE FACE, AND 1" OUTSIDE OF
SCREENED OPENING.

SCREENED OPENING.

OUTLINE OF

OUTLINE OF
FIREPLACE

FIREPLACE
FIREBRICK

FIREBRICK

COMBUSTIBLE SURROUND

COMBUSTIBLE SURROUND
MATERIALS MAY BE PLACED

MATERIALS MAY BE PLACED
WITHIN SHADED AREAS.

WITHIN SHADED AREAS.
(NOTE: COMBUSTIBLE

(NOTE: COMBUSTIBLE
MATERIALS MUST NOT

MATERIALS MUST NOT
OVERLAP BLACK PAINTED

OVERLAP BLACK PAINTED
SURFACE.)

SURFACE.)

IT IS RECOMMENDED THAT YOU
INSULATE OUTER AND INNER WALLS
OF CHASE. ALWAYS MAINTAIN THE

OF CHASE. ALWAYS MAINTAIN THE
PROPER CLEARANCE.

18" MINIMUM FROM FIREPLACE OPENING
TO BOTTTOM OF COMBUSTIBLE MANTEL,
(MANUFACTURER RECOMMENDATION).
SEE NOTE BELOW REGARDING H2853 CANOPY.

SEE NOTE BELOW REGARDING H2853 CANOPY.

NOTE:
WHEN AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED

WHEN AN APPROVED ANSI Z21.11.2 UNVENTED ROOM HEATER IS INSTALLED
IN THIS FIREPLACE, AN H2853 CANOPY MUST ALSO BE INSTALLED.

1" AIR SPACE TO SIDES
AND REAR OF FIREBOX

USE ONLY NON-COMBUSTIBLE
MATERIALS BELOW TOP
OF SPACERS.

OUTSIDE AIR INLET

SAFETY STRIP

HEARTH EXTENSION

TOP EDGE OF FIREPLACE OPENING

TOP EDGE OF FIREPLACE

INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND

INSTALLATION OF COMBUSTIBLE DECORATIVE TRIM AND THE FIREPLACE SURROUND

COMBUSTIBLE FRAMING MEMBERS
FACING MATERIAL TO TOP OF SPACERS.

COMBUSTIBLE MANTEL

12" MAXIMUM

T

RIM

I

NSTALLATION

F

IGURE

31

F

IGURE

30

F

IGURE

29

53D9032. Rev 1 03/03

Advertising