Checking gas pressure, Connecting remote receiver, Warning – Monessen Hearth VFCS20DNV User Manual

Page 15

Advertising
background image

58D6002

15

CHECkING GAS PRESSURE

and

CONNECTING REMOTE RECEIVER

MILLIVOLT CONTROL (FIGURE 11)
The valve regulator controls the burner pressure which
should be checked at the pressure test point.
If outlet pressure is low, check inlet pressure against data
plates or manual.

Turn captured slotted screw counter clockwise 2 or 3
turns and then place tubing to pressure gauge over test
point (Use test point “OUT” closest to control knob). After
taking pressure reading, be sure and turn captured screw
clockwise firmly to re-seal. Do not over torque. Check for
gas leaks.

NOTE: Remove control panel to access gas valve.

Figure 11 - Pressure Test Point Location

Millivolt Control

Test Port “OUT”

CONNECTING REMOTE RECEIVER

1. Remove cover on control panel to show opening

for remote receiver. See Figure 12.

2. Follow remote receiver Instructions to make all

necessary wiring connections.

3. Place remote receiver in the opening of control

panel. Use two screws provided to attach remote
receiver to the control panel. See Figure 12.

Figure 12 - Installing Remote Receiver

Remote Receiver

Cover

NOTE: Do not place remote in combustion chamber.

The heater gas inlet connection is 3/8" NPT at the valve.
The inlet is located on left side of stove. Remove front
control plate to better access the inlet.
When tightening up the joint to the valve, hold the valve
securely with a wrench to prevent movement.
Test all gas joints from the gas meter to the heater valve
for leaks using a gas analyzer or soap and water solu-
tion after completing connection. DO NOT USE AN OPEN FLAME.
Check the gas pressure with the appliance burning and the control set to HIGH.

W

ARNING

Connecting directly to an unregulated
propane/L.P.G. tank can cause an
explosion.