Millivolt control lighting instructions – Monessen Hearth VFCS20DNV User Manual
Page 22

22
58D6002
OPERATING INSTRUCTIONS
Figure 21 - Pilot
TO TURN OFF GAS TO HEATER
1. Turn ON/OFF switch to OFF position.
2. Turn control knob clockwise
to OFF position to completely shut off the heater.
3. If applicable: Turn off all electric power to the heater.
Figure 22 - Control Cover Plate for Millivolt
Hi/Lo Control
Ignitor/Pilot Control
On/Off Switch
(Located on Side
of Stove)
1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot.
If piezo ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, page
23.
4. Turn gas control knob clockwise
to the OFF position, turn ON/OFF switch to OFF posi-
tion.
5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell
gas, STOP! Follow the instructions under What To Do If You Smell Gas, page 21.
6. From OFF position, turn the gas control knob counterclockwise
to IGN position. Push
in control knob for 5 seconds. NOTE: If you are running the heater for the first time, it may
be necessary to press in the control knob for 30 seconds or longer to allow air to bleed
out of the gas piping.
7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from
shutting off the gas while the probe is warming up. Release the control knob.
9. Turn gas control knob counterclockwise
to the ON position.
10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch
to ON position.
11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and
call your service technician or gas supplier.
Millivolt
CONTROL LIGHTING INSTRUCTIONS