Emptying the dust canister, Removing and cleaning the filters hepa filter, Motor protection filter – Morphy Richards 73281 User Manual

Page 6: Exhaust filter, Changing the belt

Advertising
background image

66

6

EMPTYING THE

DUST CANISTER

Empty the dust canister ‡

regularly even if it does not look

full, this will maintain the

performance.

1

Unplug the cleaner from the

mains switch.

2

Press the dust canister release

button Ê and pull the canister

away from the main body H.

3

Take the canister to a dustbin.

4

Hold the dust canister over the

dustbin. Press the empty release

button Ô on the back of the

canister. This opens the door 

at the base of the canister for the

contents to be emptied-out I.

REMOVING AND

CLEANING THE

FILTERS
HEPA filter

IMPORTANT: After every empty,

clean the dust canister filter

fl

.

1

Empty the dust canister.

2

Remove the dust canister lid fi

by turning it counter-clockwise,

then lifting off J.

3

Lift the filter assembly out of the

dust canister K.

4

Lift out the mesh filter from the

filter frame by twisting it counter-

clockwise L.

5

Tap the filter over a dustbin until

no more dust falls out M.

6

You may also wash the filter in

luke-warm water, do not use

detergents. It is recommended to

wash the filter once a month or

when suction seems reduced.

Leave the filter to thoroughly air

dry before refitting into the

vacuum.

NOTE: The white material in the

filter will become discoloured

over time, this is normal and will

not affect the filter’s

performance.

IMPORTANT: Always empty the

dust canister and clean the filter

and mesh following prolonged

use. Never overfill the dust

canister. Clean the filter and

mesh screen every time the dust

canister is emptied.

Motor protection filter

The motor protection filter Ò is

located underneath the dust

canister in the air-inlet pipe.

1

Remove the dust canister.

2

Lift out the filter N and shake

over a dustbin.

The filter may also be washed in

water (no detergents). Allow the

filter to air dry. Ensure the filter is

thoroughly dry before refitting.

3

Replace the filter.

Exhaust filter

The exhaust filter Ú is located

below the dust canister

compartment.

1

Remove the dust canister.

2

Remove the exhaust filter by

twisting the motor protection

filter cover Û and lifting it away

O

.

3

Lift the filter out and shake

vigorously over a dustbin. The

filter may also be washed in luke

warm water. Do not use

detergents. The filter must be

completely dry before re-fitting.

Allow filters to air dry naturally.

4

Replace the filter and the dust

canister.

CHANGING THE

BELT

If the brush bar Ù stops

rotating, it is likely that the drive

belt ı has snapped (usually

because the brush has been

stalled). Replace the belt with the

spare belt provided. Additional

belts can be obtained from

Morphy Richards by calling the

helpline number at the base of

the page.

L

J

M

K

UUKK HHeellpplliinnee 00884444 887711 00994499

RReeppllaacceem

meenntt PPaarrttss 00884444 887733 00771155

IIrreellaanndd HHeellpplliinnee 11880000 440099 111199

I

Ê

H

Ô

73281 rev1 13/3/08 16:22 Page 6