Fp2/fp2sh, Specifications, Et-lan units  multi-communication units – Makita FP2 Series User Manual

Page 21

Advertising
background image

Xxxxx Xxxxxxxx

Xxxxx Xxxxxxxx

1

Specifications

FP2/FP2SH

ET-LAN units

Multi-communication units

Performance Specification

Transmission specifications for communication interface

16

Start-stop synchronization


RS232C RS485

Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com

Specifications

Item

Item

100BASE-TX

Item

FP2-MW

W mode

Token bus

Base band

500kbit/s

500kbit/s

500kbit/s, 250kbit/s

W2 mode

1)

F mode

Polling

Item

VE mode (PLC link)

FL-net mode

Mode
Communication method
Transmission method
Transmission speed

Transmission
distance

Number of
connectable stations
Transmission error check
Synchronization
Interface

Transmission line

RAS function

Extendable to 800m

250kbits/s: 1200m max.

500kbits/s: 800m max.

Extendable to 800m

32 stations max.

Twisted-pair cable

Hardware self-diagnosis function

Twisted-pair cables

or VCTF cables

Extendable to 700m

CRC (cyclic redundancy check) system

Start-stop synchronization

RS485 compatible

S-LINK units

FP2-SL2

1

128 points max.

CPU unit with S-LINK ports

FP2-C1SL

2

128 points max.

× 2

Item

Number of channels

Number of I/O
points

Rated power
supply voltage

Power
consumption

Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT

Connection method

* For FP2SH (Cannot be used for FP2)

1)

note 2)

note 2)

note 3)

1)

1)

1)

2)

2)

10BASE5 : 500m (2500m)
10BASE-T : 100m (500m)

FL-net [FA link protocol (UDP/IP)]

MEWTOCOL

Communication
interface
Communication speed

Cycle time
example

Cable length

Communication protocol

Link
communication
specifications

Message communication
specifications
Number of nodes

Other functions

Ethernet

10BASE5/10BASE-T

10Mbit/s

50ms/32 units

(2048 points/2048 words)

Link relay

8192 points/unit

Link register

8192 words/unit

2048 bytes max.

(Compatible with MEWTOCOL)

99 units max.

Data transfer

Remote programming

Multilevel link communications

1024 bytes max.

(Not compatible with MEWTOCOL)

254 units max.

Interconnection with other

companies' units

Communication

block used
Interface
Communication

method
Synchronization

Transmission line

Transmission distance
Transmission speed

(To be set in the system register)

Transmission code

Transmission format

(To be set in the system register)

Number of stations

PLC link capacity

COM1 (upper channel)
COM2 (lower channel)
Number of attachable units
Supported versions

General-purpose serial communications

Computer link

(Panasonic open protocol "MEWTOCOL" should be used.)

1:1 communications

1:N communications

1:1 communications

1:N communications

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

16 stations max.

Link relay: 1024 points

Link register: 128 words

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

FP2-CB485

RS485

Two-wire half duplex

FP2-CB485

RS485

Two-wire half duplex

ASCII, JIS7, JIS8, and binary

Start code: With STX / Without STX

End code: CR/CR+LF/Time setting/ETX

Data length: 7 bits/8 bits

Parity: 0/Invalid/Valid (Odd/Even)

Stop bit: 1 bit/2 bits

23 units max. (including 8 units for the computer link and 2 channels for the PLC link)

CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later

ASCII, JIS7, JIS8

PLC link function

Twisted-pair cable

or VCTF

1200m (RS485) 15m (RS232C)

115,200bps

Token passing

(Floating master)

1 master +

32 slave stations max.

Note 1: When the unit is used in W2 mode, it must be set by user programs.

The number of input and output points for each channel can be selected by the switch in the unit body

Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points

+24VDC

±10% Maximum allowable ripples (P-P): ±10%

(S-LINK terminal block IN-24VDC 1.6 A or less)

[Current consumption of the S-LINK controller (incl. D-G line current

consumption)] +24VDC 1.6A or less

[Maximum allowable current supply (Supply to the S-LINK and I/O

devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)

Bi-directional time division multiplex transmission

Bit/Frame synchronization

S-LINK protocol

28.5kbit/s

Main signal line: Extendable to 200m (max. 400m when a booster is used)

320

T-branch multi-drop wiring or standard multi-drop wiring

[+24, 0V, D-G (with a function of D-G short-circuit protection)]

Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design

Manual for details of the current consumption.

2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m

A
A

A
A

A
A

A
A

A

N/A

A: Available
N/A: Not available

* The lengths in parentheses are

available when a repeater is used.

Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the hub is

positioned close to a control board, we recommend using it at a distance of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is

positioned close to a control board, we recommend using it at a distance of 5m or less.

Communications function

Number of communication connections
Transparent

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing

Performance Specification

Transmission specifications for communication interface

Specifications

Item

Item

100BASE-TX

1)

note 2)

note 2)

note 3)

1)

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m

Notes: 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some

cases, depending on the usage environment. Also, if the hub is positioned close to a control board, we recommend using it at a distance

of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite core may be necessary in some

cases, depending on the usage environment. Also, if the transceiver is positioned close to a control board, we recommend using it at a

distance of 5m or less.

Communications function

Number of communication connections
Transparent

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing

FP2/FP2SH

Specifications

09/2007

Advertising
This manual is related to the following products: