Fp2/fp2sh, Specifications, Multi-wire link units – Makita FP2 Series User Manual

Page 22: S-link units

Advertising
background image



Xxxxx Xxxxxxxx

Xxxxx Xxxxxxxx

Xxxxx Xxxxxxxx



Multi-wire link units

Performance Specification

Transmission specifications for communication interface

16

Start-stop synchronization


RS232C RS485

Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com

Specifications

Item

Item

100BASE-TX

Item

FP2-MW

W mode

Token bus

Base band

500kbit/s

500kbit/s

500kbit/s, 250kbit/s

W2 mode

1)

F mode

Polling

Item

VE mode (PLC link)

FL-net mode

Mode
Communication method
Transmission method
Transmission speed

Transmission
distance

Number of
connectable stations
Transmission error check
Synchronization
Interface

Transmission line

RAS function

Extendable to 800m

250kbits/s: 1200m max.

500kbits/s: 800m max.

Extendable to 800m

32 stations max.

Twisted-pair cable

Hardware self-diagnosis function

Twisted-pair cables

or VCTF cables

Extendable to 700m

CRC (cyclic redundancy check) system

Start-stop synchronization

RS485 compatible

S-LINK units

FP2-SL2

1

128 points max.

CPU unit with S-LINK ports

FP2-C1SL

2

128 points max.

× 2

Item

Number of channels

Number of I/O
points

Rated power
supply voltage

Power
consumption

Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT

Connection method

* For FP2SH (Cannot be used for FP2)

1)

note 2)

note 2)

note 3)

1)

1)

1)

2)

2)

10BASE5 : 500m (2500m)
10BASE-T : 100m (500m)

FL-net [FA link protocol (UDP/IP)]

MEWTOCOL

Communication
interface
Communication speed

Cycle time
example

Cable length

Communication protocol

Link
communication
specifications

Message communication
specifications
Number of nodes

Other functions

Ethernet

10BASE5/10BASE-T

10Mbit/s

50ms/32 units

(2048 points/2048 words)

Link relay

8192 points/unit

Link register

8192 words/unit

2048 bytes max.

(Compatible with MEWTOCOL)

99 units max.

Data transfer

Remote programming

Multilevel link communications

1024 bytes max.

(Not compatible with MEWTOCOL)

254 units max.

Interconnection with other

companies' units

Communication

block used
Interface
Communication

method
Synchronization

Transmission line

Transmission distance
Transmission speed

(To be set in the system register)

Transmission code

Transmission format

(To be set in the system register)

Number of stations

PLC link capacity

COM1 (upper channel)
COM2 (lower channel)
Number of attachable units
Supported versions

General-purpose serial communications

Computer link

(Panasonic open protocol "MEWTOCOL" should be used.)

1:1 communications

1:N communications

1:1 communications

1:N communications

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

16 stations max.

Link relay: 1024 points

Link register: 128 words

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

FP2-CB485

RS485

Two-wire half duplex

FP2-CB485

RS485

Two-wire half duplex

ASCII, JIS7, JIS8, and binary

Start code: With STX / Without STX

End code: CR/CR+LF/Time setting/ETX

Data length: 7 bits/8 bits

Parity: 0/Invalid/Valid (Odd/Even)

Stop bit: 1 bit/2 bits

23 units max. (including 8 units for the computer link and 2 channels for the PLC link)

CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later

ASCII, JIS7, JIS8

PLC link function

Twisted-pair cable

or VCTF

1200m (RS485) 15m (RS232C)

115,200bps

Token passing

(Floating master)

1 master +

32 slave stations max.

Note 1: When the unit is used in W2 mode, it must be set by user programs.

The number of input and output points for each channel can be selected by the switch in the unit body

Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points

+24VDC

±10% Maximum allowable ripples (P-P): ±10%

(S-LINK terminal block IN-24VDC 1.6 A or less)

[Current consumption of the S-LINK controller (incl. D-G line current

consumption)] +24VDC 1.6A or less

[Maximum allowable current supply (Supply to the S-LINK and I/O

devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)

Bi-directional time division multiplex transmission

Bit/Frame synchronization

S-LINK protocol

28.5kbit/s

Main signal line: Extendable to 200m (max. 400m when a booster is used)

320

T-branch multi-drop wiring or standard multi-drop wiring

[+24, 0V, D-G (with a function of D-G short-circuit protection)]

Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design

Manual for details of the current consumption.

2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m

A
A

A
A

A
A

A
A

A

N/A

A: Available
N/A: Not available

* The lengths in parentheses are

available when a repeater is used.

Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the hub is

positioned close to a control board, we recommend using it at a distance of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is

positioned close to a control board, we recommend using it at a distance of 5m or less.

Communications function

Number of communication connections
Transparent

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing

S-LINK units

Performance Specification

Transmission specifications for communication interface

16

Start-stop synchronization


RS232C RS485

Note 1: The protocol can be downloaded from: www.panasonic-electric-works.com

Specifications

Item

Item

100BASE-TX

Item

FP2-MW

W mode

Token bus

Base band

500kbit/s

500kbit/s

500kbit/s, 250kbit/s

W2 mode

1)

F mode

Polling

Item

VE mode (PLC link)

FL-net mode

Mode
Communication method
Transmission method
Transmission speed

Transmission
distance

Number of
connectable stations
Transmission error check
Synchronization
Interface

Transmission line

RAS function

Extendable to 800m

250kbits/s: 1200m max.

500kbits/s: 800m max.

Extendable to 800m

32 stations max.

Twisted-pair cable

Hardware self-diagnosis function

Twisted-pair cables

or VCTF cables

Extendable to 700m

CRC (cyclic redundancy check) system

Start-stop synchronization

RS485 compatible

S-LINK units

FP2-SL2

1

128 points max.

CPU unit with S-LINK ports

FP2-C1SL

2

128 points max.

× 2

Item

Number of channels

Number of I/O
points

Rated power
supply voltage

Power
consumption

Transmission method
Synchronization
Transmission protocol
Transmission speed
Transmission distance
FAN-OUT

Connection method

* For FP2SH (Cannot be used for FP2)

1)

note 2)

note 2)

note 3)

1)

1)

1)

2)

2)

10BASE5 : 500m (2500m)
10BASE-T : 100m (500m)

FL-net [FA link protocol (UDP/IP)]

MEWTOCOL

Communication
interface
Communication speed

Cycle time
example

Cable length

Communication protocol

Link
communication
specifications

Message communication
specifications
Number of nodes

Other functions

Ethernet

10BASE5/10BASE-T

10Mbit/s

50ms/32 units

(2048 points/2048 words)

Link relay

8192 points/unit

Link register

8192 words/unit

2048 bytes max.

(Compatible with MEWTOCOL)

99 units max.

Data transfer

Remote programming

Multilevel link communications

1024 bytes max.

(Not compatible with MEWTOCOL)

254 units max.

Interconnection with other

companies' units

Communication

block used
Interface
Communication

method
Synchronization

Transmission line

Transmission distance
Transmission speed

(To be set in the system register)

Transmission code

Transmission format

(To be set in the system register)

Number of stations

PLC link capacity

COM1 (upper channel)
COM2 (lower channel)
Number of attachable units
Supported versions

General-purpose serial communications

Computer link

(Panasonic open protocol "MEWTOCOL" should be used.)

1:1 communications

1:N communications

1:1 communications

1:N communications

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

RS232C RS422

Full duplex

FP2-CB232
FP2-CB422

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

99 stations max.

(32 stations max. when our C-NET adapter is connected)

16 stations max.

Link relay: 1024 points

Link register: 128 words

Three-core or

five-core shielded wire

15m Length: 1200m max.

300 to 230,400bps

Twisted-pair cable

or VCTF

Length: 1200m max.

300 to 230,400bps

(19,200 bps when our C-NET adapter is connected)

FP2-CB485

RS485

Two-wire half duplex

FP2-CB485

RS485

Two-wire half duplex

ASCII, JIS7, JIS8, and binary

Start code: With STX / Without STX

End code: CR/CR+LF/Time setting/ETX

Data length: 7 bits/8 bits

Parity: 0/Invalid/Valid (Odd/Even)

Stop bit: 1 bit/2 bits

23 units max. (including 8 units for the computer link and 2 channels for the PLC link)

CPU unit (both FP2 and FP2SH): Ver. 1.4 or later, FPWIN GR: Ver. 2.4 or later, FPWIN PRO: Ver. 5.1 or later

ASCII, JIS7, JIS8

PLC link function

Twisted-pair cable

or VCTF

1200m (RS485) 15m (RS232C)

115,200bps

Token passing

(Floating master)

1 master +

32 slave stations max.

Note 1: When the unit is used in W2 mode, it must be set by user programs.

The number of input and output points for each channel can be selected by the switch in the unit body

Input: 0/32/64/96/128 points Output: 0/32/64/96/128 points

+24VDC

±10% Maximum allowable ripples (P-P): ±10%

(S-LINK terminal block IN-24VDC 1.6 A or less)

[Current consumption of the S-LINK controller (incl. D-G line current

consumption)] +24VDC 1.6A or less

[Maximum allowable current supply (Supply to the S-LINK and I/O

devices through the 24V - 0V line)] +24VDC 5A (Fuse: 5A or less)

Bi-directional time division multiplex transmission

Bit/Frame synchronization

S-LINK protocol

28.5kbit/s

Main signal line: Extendable to 200m (max. 400m when a booster is used)

320

T-branch multi-drop wiring or standard multi-drop wiring

[+24, 0V, D-G (with a function of D-G short-circuit protection)]

Notes: 1) Refer to the "Power Capacity Determination" section of SUNX Limited's S-LINK Design

Manual for details of the current consumption.

2) Refer to SUNX Limited's S-LINK Design Manual for the booster and FAN-OUT.

100Mbit/s

Base band

100m

205m (2 segments)

Category 5 UTP cable


100BASE-T

10Mbit/s

Base band

100m

500m (5 segments)

Category 3, 4 and 5 UTP cable


100BASE5

10Mbit/s

Base band

500m

2500m (5 segments)

Transceiver cable

50m

100 nodes/segment

Integer multiples of 2.5m

A
A

A
A

A
A

A
A

A

N/A

A: Available
N/A: Not available

* The lengths in parentheses are

available when a repeater is used.

Notes 1) Switching between 100BASE-TX and 10BASE-T is done automatically by auto negotiation function.

2) The standards cite 100m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the hub is

positioned close to a control board, we recommend using it at a distance of 10m or less.

3) The standards cite 50m as the maximum, but noise resistance measures such as attaching a ferrite

core may be necessary in some cases, depending on the usage environment. Also, if the transceiver is

positioned close to a control board, we recommend using it at a distance of 5m or less.

Communications function

Number of communication connections
Transparent

communications buffer

Transmit

Receive

- MEWTOCOL-COM: computer link function (max. 2KB)

- MEWTOCOL-DAT: data transfer (max. 1020 words)

- Transparent communication
8 connections max.
Factory setting: 1k words/connection x 3
Factory setting: 1k words/connection x 3

Transmission speed
Transmission method
Max. segment length
Max. distance between nodes
Communication cable or connection
Max. transceiver cable
length
Max. number of nodes
Node spacing

Item

Transistor

Line driver

Output type
Number of axes controlled
Position

command

Speed
command

Acceleration/
deceleration
command

Home return




Operation mode




Startup time
Output interface
Feedback
counter

Other functions

Internal current consumption (at 5 VDC)

External power

supply

Command units
Max. pulse count
Command
range

Acceleration/
deceleration

“S” Acceleration/
deceleration
Acceleration/
deceleration time
Home return speed
Input terminals
Output terminals

Output mode
Countable range
Input mode

Voltage
Current consumption

FP2-PP21

FP2-PP41

FP2-PP22

FP2-PP42

21.6VDC to 26.4VDC

200mA max.

50mA

350mA max.

90mA

200mA max.

50mA

350mA max.

90mA

Notes: Previous FP2 positioning units FP2-PP2 and FP2-PP4 are not compatible with the multi-function
type FP2 positioning unit. Please contact us.

* 2-phase input cannot be used with multiples of one.

2-axis type

FP2-PN2AN

4-axis type

FP2-PN4AN

8-axis type

FP2-PN8AN

Speed control function
Torque control function

Product number

Home
return

Others

Communication speed
Cables
Connection system

Communication cycle/
Number of connectable stations
Transmission distance

Counter

Interrupt

Part no.

Product number

Output
specifi-
cations

Counter

Pulse
output

PWM
output

Insulation method
Rated voltage
Rated current
Input impedance
Usage voltage range
Min. ON voltage/Min. ON current
Min. OFFvoltage/Min. OFFcurrent
Response
time

Input time constant setting
Common method
Number of counter channels
Calculation range
Max. calculation speed
Input modes
Max. calculation speed
Other
Number of interrupt points
Interrupt processing

delays
Insulation method
Rated load voltage
Rated load voltage range
Max. load current
Leakage current when off
Max. voltage drop when on
Response

time

Surge absorber
Common method

External power

supply

Surge absorber
Channels
Max. output frequency
Output modes
Number of output points
Max. load current
Cycle
Duty

Item

Item

OFF

ON

ON

OFF

OFF

ON

ON

OFF

Voltage
Current

(when using 24VDC)

FP2 High-speed counter unit

FP2-HSCT (NPN)
FP2-HSCP (PNP)

FP2 Pulse I/O unit

FP2-PXYT (NPN)

Photocoupler insulation

24VDC

Approx. 7.5mA (when using 24VDC)

Approx. 3.2k

20.4VDC to 26.4VDC

19.2V /6mA

5.0V /1.5mA

1

µs or less

2

µs or less

None, 4

µs, 8µs, 16µs, 32µs (set in 2-input units)

16 points/common (+ common)

4 channels

32-bit with sign (–2147483648 to +2147483647)

200kHz

3 modes (direction control, individual input, phase input)

2.5

µs

8 comparison outputs, multiplier function (1, 2, 4)

None, 1/unit, 8/unit (set with mode setting switches)

160

µs max. (when using FP2 CPU unit)

50

µs max. (when using FP2SH CPU unit)

Photocoupler insulation

5 to 24VDC

4.75VDC to 26.4VDC

0.1A (A11 to A18, B11 to B14 pins), 0.8A (B15 to B18 pins)

1

µA max.

0.5V max.

1

µs max.

1

µs or less (NPN)

5

µs or less (PNP)

Zener diode

16 points/common

20.4VDC to 26.4VDC

90mA or less (NPN)

200mA or less (PNP)

8 points (A11 to A18 pins)

4CH (B11 to B18 pins)

100kHz

2 modes (direction control, individual output)

4CH (B15 to B18 pins)

0.8A

1Hz to 30kHz

0 to 100% (unit: 1%)

1)

1)

2)

3)

3)

1)

1pps to 500kpps

(can set in 1pps)

1pps to 4Mpps

(can set in 1pps)

Unit specifications

Position
control
function

Control method
Interpolation control
Unit of control
Positioning data
Backup
Acceleration/
deceleration method
Acceleration/
deceleration time
Positioning range

Search method
Creep rate

Communication specifications

PTP control, continuous path (CP) control

Two/Three-axis linear interpolation, two-axis circular interpolation, three-axis helical interpolation

Pulse/

µm/inch/degree

600 points per axis

Parameters and data tables can be saved in FROM

Linear/S-curve acceleration and deceleration

0 to 10,000ms (in increments of 1ms)

(-1073741823 to +1073741823 pulses) Increment/Absolute specification

Supported by a JOG operation (free-run operation)

Supported by a real-time torque control function

Home proximity (DOG) search

Can be set freely

Pulser input operation supported

Auxiliary output code and auxiliary output contact

Dwell time

In-position contact

100Mbps

Commercially available LAN straight cable (Category 5e shielded cable)

Ring

0.5ms, 8 axes max./system (Command cycle: 1ms)

Between terminals: 60m Total: 200m

2 axes, independent 4 axes, independent 2 axes, independent 4 axes, independent

Pulse unit (the program specifies whether Increment or Absolute is used.)

Signed 32 bits (–2147483648 to +2147483647 pulses)

Linear acceleration/deceleration,

S acceleration/deceleration (this takes the form of an “S”)

Can select from Sin curve, Secondary curve,

Cycloid curve and Third curve

0 to 32,767ms (can set in 1ms)

Speed setting possible (changes return speed and search speed)

Home input, Near home input, Over limit input (+), Over limit input (–)

Deviation counter clear output signal

E point control (Linear and S accelerations/decelerations selecting possible)
P point control (Linear and S accelerations/decelerations selecting possible)
Home return function (Home search)
JOG operation function
JOG positioning function
Pulser input function
Transfer multiplication ratio
(

Ч1, Ч2, Ч5, Ч10, Ч50, Ч100, Ч500, Ч1000 selecting possible)

Real-time frequency change function
Infinity output function

0.02ms or 0.005ms possible

1 pulse output (Pulse/Sign), 2 pulse output (CW/CCW)

Signed 32-bit (–2147483648 to +2147483647 pulse)

2-phase input*, Direction distinction input, Individual input (transfer multiple available for each)

The flag to compare the elapsed value is built-in

(The timing signal outputs at the optional position during an operation)

Notes:
1) This value is effective when the input time constant (filter) setting was set to "No setting".
2) If interrupts are used at the 1/unit setting, the interrupt from the external input terminal B1 (X8) or

the interrupt program from the comparison 0 (one of among INT16 to INT23) is booted.

3) At maximum load current and resistance load. There may be distortion in the output waveform,

depending on the load current and type of load.

Positioning units: RTEX (Network type)

FNS (Flexible Network Slave) specifications:

FP2/FP2SH

Specifications

NEW!

Item

PROFIBUS

DeviceNet

CANopen

Baud rate

• Automatic baud rate detection

• 9.6 kbaud to 1Mbaud

• Automatic baud rate detection

• 15kbps to 500kbps

• Automatic baud rate detection

• 10kbps to 1Mbps

Isolation

Galvanically isolated bus electronics

Galvanically isolated bus electronics

Galvanically isolated bus electronics

Connection types

DP-V0: process data is accessed from the

PROFIBUS network as cylical I/O data

• Cyclic connections

• COS (Change of State)

• Bit strobe connections

• Polled connections

• Explicit connections

PDO (Process Data Object)

Exchange via:

• Cyclic Synchronous

• Acyclic Synchronous

• COS

• Timer-driven connections

Maximum

inputs / outputs

6 words altogether for inputs and outputs

(in units of 1,  or 4 words)

E. g. for cyclic connections:

18 words in each direction

Data 18 words

(for TPDOs and RPDOs)

Additional features

Diagnostic support

• UCMM capable

• CIP parameter object

• Diagnostic support

Diagnostic support

09/2007