Technical specifications – Motorola FD-1 User Manual

Page 8

Advertising
background image

English

FD-1

Page 22

Auxiliary functions F1 to F4
The auxiliary functions F1 to F4 can be switched via the central unit.
They are available for the switching of optional accessories (e.g. cab
lighting, carriage lighting, smoke generator, noise module).

Point connections

X1 to X4

Solder points for setting the address.

X5 and X6

Connections to the rails. X5 must be connected to the
central conductor.

X7

Accessory /-ies with a maximum current consumption of
800 mA*. Switched via F3.

X8

Accessory /-ies with a maximum current consumption of
500 mA*. Switched via F4.

X9

Accessory /-ies with a maximum current consumption of
800 mA*. Switched via F1.

X10

Accessory /-ies with a maximum current consumption of
800 mA*. Switched via F2.

* Maximum current consumption of all accessories = 1.000 mA!

Technical specifications

Data format

Motorola I

Supply voltage

12-24 Volt digital voltage

Current consumption
(without connected loads)

ca. 10 mA

Max. current per function output

500 resp. 800 mA

Max. total current

1.000 mA

Protected to

IP 00

Ambient temperature in use

0 - + 60° C

Ambient temperature in storage

-10 - + 80° C

Comparative humidity allowed

max. 85 %

Dimensions

ca. 18 x 35 x 4 mm

Weight

ca. 2 g