NPort 5400 Series User’s Manual

Web Console Configuration

5-25

Reverse Telnet Mode

TCP alive check time

Setting

Factory Default

Necessity

0 to 99 min

0

Optional

Specifies the time slice for checking if the TCP connection is alive. If no response, NPort 5400 series
will disconnect the original connection.

Inactivity time

Setting

Factory Default

Necessity

0 to 65535 ms

0

Optional

Idle time setting for auto-disconnection. 0 min. means it will never disconnect.

Local TCP port

Setting

Factory Default

Necessity

1 to 65535

4001

Optional

Each of NPort’s serial ports is mapped to a TCP port. To avoid conflicts with TCP ports, set port
numbers to 4001 for port1, 4002 for port 2, etc. (like the default values).

Map <CR-LF>

Setting

Factory Default

Necessity

CR, LF, or CR-LF

CR-LF

Optional

If data received through NPort 5400’s Ethernet port is sent using the “enter” command, the data will be
transmitted out the serial port with an added

(1) “carriage return + line feed” if you select the <CR-LF> option

(i.e., the cursor will jump to the next line, and return to the first character of the line)

(2) “carriage return” if you select the <CR> option

(i.e., the cursor will return to the first character of the line)

(3) “line feed” if you select the <LF> option.

(i.e., the cursor will jump to the next line, but not move horizontally)