SECTION 2

INSTALLATION

13

WARNING

DO NOT USE CONDUIT OR GAS LINE

FOR GROUND CONNECTION.

CAUTION

IT IS RECOMMENDED THAT THE OVEN

BE PLACED UNDER A VENTILATION

HOOD FOR ADEQUATE AIR SUPPLY

AND VENTILATION.

ELECTRIC SUPPLY TO BE

PROVIDED BY CUSTOMER

CIRCUIT BREAKER
Separate circuit breaker with lockout/tagout electrical

shutoff for each oven. Wire each oven separately.
15A Amp circuit breaker for 208-240V.
ELECTRICAL SPECIFICATIONS
DOMESTIC:
208V main blower motors, 1 Ph, 1.5 Amp

draw, 50/60 Hz, 208-240V control circuit, 2 pole, 3 wire

system per oven (2 hot, 1 grd).
Do

NOT use conduit for ground.

or
DOMESTIC or EXPORT:
240V main blower motors, 1

Ph, 1.5 Amp draw, 50/60 Hz, 208-240V control circuit, 2

pole, 3 wire system per oven (2 hot, 1 grd).
230V main blower motors, 1 Ph, 1.5 Amp draw, 50/60 Hz,

208-240V control circuit, 2 pole, 3 wire system per oven

(2 hot, 1 grd).
Do

NOT use conduit for ground.

A 6 foot cord with a NEMA L6-20 plug is supplied on

Domestic units.
POWER RATING
50,000 BTU/hr (14.7 kW/hr.)
SUPPLY WIRE
Supply wire size must be in accordance with the National

Electrical Code (current edition) and must be in compli-

ance with local codes.
SUGGESTED
If space permits, service should be located near the

control console end of the oven(s) to allow convenient

access to safety switches.

UTILITY ROUGH-IN DIMENSIONS AND POSITIONING

FOR PS528-SERIES OVENS

CAUTION

UNIT MUST HAVE AIR VENT PLATES

INSTALLED OR WARRANTY WILL BE VOID.

II. VENTILATION GUIDELINES

A mechanically driven ventilation system is required for

the PS528 Series Middleby Marshall conveyorized gas

ovens.
Local codes and conditions vary greatly from one area

to another and must be complied with. Following are

the suggested requirements for good ventilation. Please

remember these are recommendations or guidelines, you

may have a special condition or problem that will require

the services of a ventilation engineer or specialist. Proper

ventilation is the oven owner’s responsibility. Improper

ventilation can inhibit oven performance.
Please Note: There are now two “stand off” ‘C’ Chan-

nels and “Heat Guards” for “Double and Triple Ovens”

that must be installed in the field.
Please Note: There is now one heat guard on dou-

ble units and two heat guards on triple units. See

Figure 2-7.
These ‘C’ Channel brackets are installed in the vertical

plane using existing screws (Item 6) to support these ‘C’

Channels using the upper and lower Key Hole openings

in the ‘C’ Channels. The ‘C’ Channels are identical and

once installed will allow ample amounts of air through

the cooling fan mounted on the rear side of the oven by

keeping the oven away from the rear wall.

Figure 2-9. Typical PS528-Series Oven(s)

Installation