V. gas supply caution, Figure 2-15 - flexible gas hose installation – Middleby Marshall Oven PS528G User Manual

Page 19

Advertising
background image

SECTION 2

INSTALLATION

15

V. GAS SUPPLY

CAUTION

DURING PRESSURE TESTING NOTE THE FOLLOWING:
1. The oven and its individual shutoff valve must be dis-

connected from the gas supply piping system during any

pressure testing of that system at test pressure in excess

of 1/2 psi (3.45 kPa).
2. The oven must be isolated from the gas supply piping

system by closing its individual manual shutoff valve dur-

ing any pressure testing of the gas supply piping system

at test pressure equal to or less than 1/2 psi (3.45 kPa).
3. If incoming pressure is over 14" W.C. (35mbar), a sepa-

rate regulator MUST be installed in the line BEFORE the

individual shutoff valve for the oven.
WARNING:
To prevent damage to the control valve regu-

lator during initial turn- on of gas, it is very important to

open the manual shutoff valve very slowly.
After the initial gas turn-on, the manual shutoff valve must

remain open except during pressure testing as outlined

in the above steps or when necessary during service

maintenance.

A. Gas Utility Rough-In Recommendations
The following gas system specifications are STRONGLY

RECOMMENDED. Deviating from these recommendations may

affect the baking performance of the oven.
Gas Meter - 650 cfh (307

/min) meter

Gas Line

DEDICATED LINE from the gas meter to the oven

1-1/2" (38.1mm) pipe for natural gas

1-1/2" (38.1mm) pipe for propane

Maximum length: 200' (61m). Each 90° elbow equals 7'

(2.13m) of pipe.

Figure 2-15 - Flexible Gas Hose Installation

B. Gas Conversion
Where permitted by local and national codes, it is possible to

convert ovens from natural to propane gas, or from propane to

natural gas. Use the appropriate Middleby Gas Conversion Kit

for the specific oven model.

CAUTION: The terms of the oven’s warranty require all start-

ups, conversions and service work to be performed

by a Middleby Authorized Service Agent.

C. PS528 Propane Conversion
Two items have to be changed, to change the oven to LP:
1. Replace main orifices.
2. Adjust main gas regulator per instructions below.
Disconnect the manifold union closest to the main burner, and

remove the manifold assembly (four screws). Slide out the manifold

assembly (leaving the ignition and sense wires connected).

Replace the main orifices.
Replace the main orifices on the manifold assemblies with the LP

units, and replace the manifold assembly. Reconnect the union.
D. Adjusting the Maximum Pressure Setting
1. Disconnect pressure feedback connection (if applicable).
2. Connect a suitable pressure gauge to pipe line or to outlet

pressure tap of gas control concerned, to measure burner

pressure (measuring point must be as near to burner as

possible).

3. Make sure that the appliance is in operation and the Moduplus

®

coil is energized with maximum current.

4. If maximum rate pressure needs adjustment, use an 8 mm

wrench to turn adjustment screw for maximum pressure setting

(clockwise to increase or counter-clockwise to decrease

pressure), until the desired maximum outlet pressure is

obtained.

5. Disconnect electrical connection of the Moduplus

®

.

6. Check minimum pressure setting and readjust if necessary.

(See Adjusting Minimum Pressure Setting for proper adjusting

procedure.)

7. Reconnect pressure feedback connection (if applicable).
8. If minimum and maximum pressures are set, wire the

Moduplus

®

in circuit.

9. Close pressure tap screw.

E. Adjusting the Minimum Pressure Setting
1. Disconnect pressure feedback connection (if appcable).
2. Connect a suitable pressure gauge to pipe line or to outlet

pressure tap of gas control concerned, to measure burner

pressure (measuring point must be as near to burner as

possible).

3. Disconnect electrical connection of the Moduplus

®

.

4. Energize operator, set control in operation and wait until an

outlet pressure is recorded on pressure gauge.

5. If minimum rate pressure needs adjustment, use an 8 mm

wrench to turn adjustment screw for minimum pressure setting

(clockwise to increase or counter-clockwise to decrease

pressure), until the desired minimum outlet pressure is

obtained.

6. Check if main burner lights easily and reliable at minimum

pressure.

7. Reconnect pressure feedback connection (if applicable).
8. Close pressure tap screw.

To Gas

Supply

Pipe

90°

Elbow

Quick-

disconnect

device

Flexible

Gas Hose

Full-Flow

Gas

Shutoff

Valve

3/4" gas

pipe nipple

3/4"-1/2"

gas pipe

reducer

Individual gas

connection

for each oven

cavity

1/2" gas

pipe nipple

1/2" gas

line tee with

pressure tap

Advertising