Power Supply

The BLE*/* power supply is a separate circuit board mounted to the underside of the amplifier
module and is capable of 60 Vac or 90 Vac powering. The power supply provides a regulated
24 Vdc output over an ac input between 38 Vrms and 90 Vrms with a line frequency from 50 Hz
through 60 Hz. Potentiometer R25 adjusts the output voltage to 24 Vdc, however, this is set at
the factory and field adjustment is not recommended.

Figure 2-6 illustrates the components on the power supply:

Figure 2-6
BLE*/* power supply

P2-3

P2-2

W1

P2-1

C2

4

C25

C26

C2

L2

C7

C6

C5

L1

C3

D6

D5

D7

U1

T1

C12

U2

C10

J1

LO

HI

C1

C22

R25

C11

U4

U3

L3

C17

Q1

X2

R1

6

E1

E2

D8

SURGE PROTECTOR

X1

D1

L8

P1

1

R25

Surge protector

or FTEC

LO/HI

selector

The power supply also contains a two-position

LO

/

HI

selector that sets the start-up voltage for

38 Vac or 55 Vac. The BLE*/* is shipped with the selector in the

LO

position which is the

standard configuration. The selector should be switched to the

HI

position only for a 90 Vac

system. This sets the start-up voltage at 55 Vac. Because this is only 5 V below 60 Vac, it is not
practical in a 60 Vac system. There is no damage to the amplifier if the selector is not changed
from the standard

LO

setting. However, changing the selector ensures that the dc supply does

not turn on until the proper input voltage, 38 Vac or 55 Vac, is reached. This prevents excessive
loading of the system power supply during turn-on after a system shutdown.

You must remove the power supply cover to access the selector illustrated in Figure 2-6.
Section 3, “Amplifier Setup” explains changing the setting of this selector to meet system
requirements.

The power supply includes a heavy-duty gas discharge tube that you can replace with the
optional fast-transfer electronic-crowbar (FTEC) surge protector. The FTEC is a crowbar circuit
that fires at approximately 245 V and presents a short circuit to the line during periods of
overvoltage. After the ac input voltage returns to normal, the FTEC resumes its open state.

The factory-installed 20-ampere fuse, illustrated in Figure 2-8, provides power-passing to
additional line extenders.