4-2

Bench Testing

BLE*/* Installation and Operation Manual

Test Equipment and Connections

The equipment typically used for testing the BLE*/* consists of a network analyzer such as the
HP 8712 or 8713 series, a 60/90 Vac bench power supply, a cable simulator, a Motorola model
SSP-PIN power combiner, and a variety of jumper cables, adapters, and fittings.

CAUTION!

To protect the network analyzer and sweep comparator, you must configure the SSP-PIN power combiner to block ac
power from the input port.

Fabricate a cable simulator that you can configure to provide the desired cable loss in 1 dB
increments up to approximately 30 dB. Then, connect the test equipment as shown in
Figure 4-1:

Figure 4-1
Test equipment connections for bench sweeping

A

S

SE

M B LE

D

I

N

M

E X

I C

O

4

2

6

3

1

5

Network

analyzer

BLE-*/*

under test

Cable

simulator

Power

combiner

117
Vac

AC power

supply

60/90 Vac

Sweep

input

Sweep

output

CAUTION!

Before you begin the following subsection, remove the input pad,

JXP

-

IN

, to avoid damage to the hybrids before you

apply power.

Measuring Forward Gain

This subsection provides instructions for measuring the full gain and the operational gain and
flatness of the BLE*/*.

To measure the full gain of the amplifier:

1

Determine whether the power-supply jumper (J1) is positioned for

LO

or

HI

operation.

2

Connect the BLE*/* to the test equipment as illustrated in Figure 4-1 and apply power.

3

Verify that the dc voltage is 24 V

± 0.4 V and re-install the input pad.

4

Apply the sweep signal and adjust test equipment as needed.

5

Select manual gain by placing the drive control select jumper in the

MAN

position and turn

the

MANUAL LEVEL

control (Figure 2-8) fully clockwise.

Advertising