7 reliability, 8 environmental – Intel D945GCLF2 User Manual

Page 55

Advertising
background image

Technical Reference

55

2.7

Reliability

The Mean Time Between Failures (MTBF) prediction is calculated using component and
subassembly random failure rates. The calculation is based on the Bellcore Reliability
Prediction Procedure, TR-NWT-000332, Issue 4, September 1991. The MTBF
prediction is used to estimate repair rates and spare parts requirements.

The MTBF data is calculated from predicted data at 55 ºC. The Intel Desktop Board
D945GCLF2 MTBF is 75,716.67728 hours.

2.8

Environmental

Table 25 lists the environmental specifications for the board.

Table 25. Intel Desktop Board D945GCLF2 Environmental Specifications

Parameter Specification

Temperature

Non-Operating -20

°C to +70 °C

Operating

0 °C to +55 °C

Shock

Unpackaged

50 g trapezoidal waveform

Velocity change of 170 inches/second²

Packaged

Half sine 2 millisecond

Product weight (pounds)

Free fall (inches)

Velocity change
(inches/sec²)

<20

36

167

21-40

30

152

41-80

24

136

81-100

18

118

Vibration

Unpackaged

5 Hz to 20 Hz: 0.01 g² Hz sloping up to 0.02 g² Hz

20 Hz to 500 Hz: 0.02 g² Hz (flat)

Packaged

10 Hz to 40 Hz: 0.015 g² Hz (flat)

40 Hz to 500 Hz: 0.015 g² Hz sloping down to 0.00015 g² Hz