Bit

Description

1

Cash receipt right home position. Set to 1 when the printhead is in the
customer receipt right home position.

2

Left home position. Set to 1 when the printhead is in the left home position.

3

Document right home position. Set to 1 when the printhead is in the document
right home position.

4

Reserved. Always 0.

5

Ribbon cover open. Set to 1 when the ribbon cover is open.

6

Cash receipt print error. Paper cover is open, the customer receipt station is out
of paper, or the cutter is jammed in the closed position.

7 (MSB)

Command reject.

Status Byte 2

Bit

Description

0 (LSB)

Document ready. Set to 0 when the document insert station is ready for
printing. This occurs when both document sensors detect the document and the
document has been fed to the first print position.

1

Document present under the front sensor. Set to 0 when a document is under
the front document sensor.

2

Document present under the top sensor. Set to 0 when a document is under
the top document sensor.

3

Reserved. Always equals 1.

4

Print buffer held. Set to 1 when the print buffer is being held. Cleared when
buffer released.

5

Open throat position. Set to 1 when the printhead is in the open throat position.

6

Buffer empty. Set to 1 when no print data and no commands are in the buffer.

7 (MSB)

Buffer Full. Set when only 1K bytes are available in the buffer.

Status Byte 3

Bit

Description

0 (LSB)

Memory sector is full.

1

Home error.

2

Document error. The document was not inserted after the document station
was selected, and the wait subsequently timed out.

3

Flash EPROM load error or MCT load error.

4

Reserved. Always equals 0.

5

User flash storage sector is full.

6

Firmware error. CRC on the firmware failed. The printer is running out of the
boot sector. Only system commands and firmware commands are accepted.

7 (MSB)

Command complete (“Erase Flash EPROM Sector” on page 121, and whenever
a physical line is printed). Set to 1 when the command is complete or a
physical line is printed.